Back to Search Start Over

Automated titanium fastener for surgical aortic valve replacement—preventive role for infective endocarditis?

Authors :
Kahrovic, Amila
Herkner, Harald
Angleitner, Philipp
Werner, Paul
Kocher, Alfred
Ehrlich, Marek
Wiedemann, Dominik
Laufer, Guenther
Simon, Paul
Andreas, Martin
Source :
European Journal of Cardio-Thoracic Surgery. Jun2024, Vol. 65 Issue 6, p1-8. 8p.
Publication Year :
2024

Abstract

OBJECTIVES Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20–0.94, P  = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60–1.09, P  = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63–1.07, P  = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47–1.45, P  = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P  = 0.032). CONCLUSIONS Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10107940
Volume :
65
Issue :
6
Database :
Academic Search Index
Journal :
European Journal of Cardio-Thoracic Surgery
Publication Type :
Academic Journal
Accession number :
178159435
Full Text :
https://doi.org/10.1093/ejcts/ezae236