Back to Search Start Over

6-mm shunt transjugular intrahepatic portosystemic shunt in patients with severe liver atrophy and variceal bleeding.

Authors :
Yan, Huzheng
Xiang, Zhanwang
Zhao, Chenghao
Luo, Shuyang
Liu, Huan
Li, Mingan
Huang, Mingsheng
Source :
European Radiology. Jul2024, Vol. 34 Issue 7, p4697-4707. 11p.
Publication Year :
2024

Abstract

Objectives: We proposed a strategy for the creation of a 6-mm transjugular intrahepatic portosystemic shunt (TIPS) and to assess its effectiveness compared to a conventional 8-mm shunt for TIPS-induced hepatic encephalopathy (HE). Methods: Patients were reviewed retrospectively using propensity score matching (1:1) and divided into 6-mm and 8-mm shunt groups based on shunt diameter. The stent patency, HE incidence, and rebleeding rate between the two groups were then compared. Results: From January 2018 to June 2021, both 6-mm shunt group and 8-mm shunt group included 58 patients. The 6-mm shunt group had significantly smaller liver volumes (879.3 ± 237.1 vs. 1008.8 ± 293.0; p = 0.010), and the median stent patency times were 30.7 and 33.8 months in the 6-mm and 8-mm groups, respectively (p = 0.124). No statistically significant difference was found between the two groups in the 1-year (8.6% vs. 3.4%; p = 0.242) and 2-year (17.2% vs. 12.1%; p = 0.242) rebleeding rates. The 1-year cumulative incidences of overt HE were 12.1% and 27.6% in the 6-mm and 8-mm groups, respectively (p = 0.040), and the 2-year cumulative overt HE incidences in these groups were 19.0% and 36.2%, respectively (p = 0.038). Notably, patients with a 6-mm shunt also experienced less hepatic impairment. Conclusions: For patients with variceal bleeding and a small liver volume, the 6-mm shunt significantly reduced the incidence of overt HE, protected perioperative liver function, and did not affect stent patency or rebleeding rate. Clinical relevance statement: For patients with variceal bleeding with small liver volume, the 6-mm transjugular intrahepatic portosystemic shunt (TIPS) significantly reduced the incidence of overt hepatic encephalopathy after TIPS, protected perioperative liver function, and did not affect stent patency and rebleeding rate. Key Points.: • A strategy for the creation of a 6-mm transjugular intrahepatic portosystemic shunt for patients with variceal bleeding and a small liver volume was proposed. • The 6-mm transjugular intrahepatic portosystemic shunt significantly reduced the incidence of overt hepatic encephalopathy. • The 6-mm transjugular intrahepatic portosystemic shunt did not affect stent patency or rebleeding rate. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09387994
Volume :
34
Issue :
7
Database :
Academic Search Index
Journal :
European Radiology
Publication Type :
Academic Journal
Accession number :
178150554
Full Text :
https://doi.org/10.1007/s00330-023-10346-3