Optimizing vestibular implant electrode positioning using fluoroscopy and intraoperative CT imaging.

Authors :
Loos, Elke
Stultiens, Joost J. A.
Volpe, Benjamin
Vermorken, Bernd L.
Van Boxel, Stan C. J.
Devocht, Elke M. J.
van Hoof, Marc
Postma, Alinda A.
Guinand, Nils
Pérez-Fornos, Angelica
Van Rompaey, Vincent
Denys, Sam
Desloovere, Christian
Verhaert, Nicolas
van de Berg, Raymond
Source :
European Archives of Oto-Rhino-Laryngology. Jul2024, Vol. 281 Issue 7, p3433-3441. 9p.
Publication Year :
2024

Abstract

Purpose: Vestibular implant electrode positioning close to the afferent nerve fibers is considered to be key for effective and selective electrical stimulation. However, accurate positioning of vestibular implant electrodes inside the semicircular canal ampullae is challenging due to the inability to visualize the target during the surgical procedure. This study investigates the accuracy of a new surgical protocol with real-time fluoroscopy and intraoperative CT imaging, which facilitates electrode positioning during vestibular implant surgery. Methods: Single-center case-controlled cohort study with a historic control group at a tertiary referral center. Patients were implanted with a vestibulocochlear implant, using a combination of intraoperative fluoroscopy and cone beam CT imaging. The control group consisted of five patients who were previously implanted with the former implant prototype, without the use of intraoperative imaging. Electrode positioning was analyzed postoperatively with a high-resolution CT scan using 3D slicer software. The result was defined as accurate if the electrode position was within 1.5 mm of the center of the ampulla. Results: With the new imaging protocol, all electrodes could be positioned within a 1.5 mm range of the center of the ampulla. The accuracy was significantly higher in the study group with intraoperative imaging (21/21 electrodes) compared to the control group without intraoperative imaging (10/15 electrodes), (p = 0.008). Conclusion: The combined use of intraoperative fluoroscopy and CT imaging during vestibular implantation can improve the accuracy of electrode positioning. This might lead to better vestibular implant performance. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09374477
Volume :
281
Issue :
7
Database :
Academic Search Index
Journal :
European Archives of Oto-Rhino-Laryngology
Publication Type :
Academic Journal
Accession number :
178130484
Full Text :
https://doi.org/10.1007/s00405-023-08428-5