Back to Search Start Over

The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types.

Authors :
Lee, Kun-Han
Hung, Yueh-Ting
Chang, Cheng-Yang
Wang, Jui-Chien
Tsai, Shang-Wen
Chen, Cheng-Fong
Wu, Po-Kuei
Chen, Wei-Ming
Source :
Archives of Orthopaedic & Trauma Surgery. Jun2024, Vol. 144 Issue 6, p2839-2847. 9p.
Publication Year :
2024

Abstract

Introduction: The choice between a cementless taper wedge stem and a fit-and-fill stem in total Hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly evaluated. This study aimed to compare the risk of stem-related complications between these two stem types in Dorr type A, B, and C femurs. Materials and Methods: From January 2015 through April 2021, we retrospectively reviewed 1995 cementless THA procedures. We stratified all procedures into three groups: Dorr type A (N = 360, 18.0%), B (N = 1489, 74.7%) and C (N = 146, 7.3%). The primary outcome domain was stem-related complications, including stem subsidence ≥ 3 mm, intraoperative fracture, periprosthetic fracture and aseptic stem loosening. We performed multivariate regression analysis to compare the risk of stem-related complication between the two stem types. Other factors included age, sex, body mass index, diagnosis, age-adjusted Charlson comorbidity index, stem alignment and canal fill ratio. Results: The incidence of stem-related complications in the taper wedge and fit-and-fill stem groups was 4.4% (N = 15) and 6.5% (N = 107), respectively. Fit-and-fill stems showed an increased risk of stem-related complications (aOR: 9.903, 95% CI: 1.567–62.597) only in Dorr type C femurs. No significant difference in risk was observed in Dorr type A and B femurs. Furthermore, the canal fill ratio at the lesser trochanter, 2 cm and 7 cm below the lesser trochanter, did not exhibit an association with stem-related complications in any Dorr type. Conclusions: Concerning the risk of stem-related complications, the taper wedge stem was a better choice in Dorr type C femurs. However, there was no difference in risk between the taper wedge stem and fit-and-fill stem in Dorr type A and B femurs. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09368051
Volume :
144
Issue :
6
Database :
Academic Search Index
Journal :
Archives of Orthopaedic & Trauma Surgery
Publication Type :
Academic Journal
Accession number :
178130287
Full Text :
https://doi.org/10.1007/s00402-024-05361-y