Back to Search Start Over

Dual Layer vs Single Layer Woven EndoBridge Device in the Treatment of Intracranial Aneurysms: A Propensity Score‑Matched Analysis.

Authors :
Dmytriw, Adam A.
Salim, Hamza
Musmar, Basel
Aslan, Assala
Cancelliere, Nicole M.
McLellan, Rachel M.
Algin, Oktay
Ghozy, Sherief
Dibas, Mahmoud
Lay, Sovann V.
Guenego, Adrien
Renieri, Leonardo
Carnevale, Joseph
Saliou, Guillaume
Mastorakos, Panagiotis
El Naamani, Kareem
Shotar, Eimad
Premat, Kevin
Möhlenbruch, Markus
Kral, Michael
Source :
Neurosurgical Review. 3/14/2024, Vol. 47 Issue 1, p1-12. 12p. 5 Charts, 2 Graphs.
Publication Year :
2024

Abstract

Background The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. Methods A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. Results Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). Conclusion The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03445607
Volume :
47
Issue :
1
Database :
Academic Search Index
Journal :
Neurosurgical Review
Publication Type :
Academic Journal
Accession number :
178009820
Full Text :
https://doi.org/10.1007/s10143-024-02341-z