Back to Search Start Over

Can 3D Multiparametric Ultrasound Imaging Predict Prostate Biopsy Outcome?

Authors :
Chen, Peiran
Turco, Simona
Wang, Yao
Jager, Auke
Daures, Gautier
Wijkstra, Hessel
Zwart, Wim
Huang, Pintong
Mischi, Massimo
Source :
Ultrasound in Medicine & Biology. Aug2024, Vol. 50 Issue 8, p1194-1202. 9p.
Publication Year :
2024

Abstract

To assess the value of 3D multiparametric ultrasound imaging, combining hemodynamic and tissue stiffness quantifications by machine learning, for the prediction of prostate biopsy outcomes. After signing informed consent, 54 biopsy-naïve patients underwent a 3D dynamic contrast-enhanced ultrasound (DCE-US) recording, a multi-plane 2D shear-wave elastography (SWE) scan with manual sweeping from base to apex of the prostate, and received 12-core systematic biopsies (SBx). 3D maps of 18 hemodynamic parameters were extracted from the 3D DCE-US quantification and a 3D SWE elasticity map was reconstructed based on the multi-plane 2D SWE acquisitions. Subsequently, all the 3D maps were segmented and subdivided into 12 regions corresponding to the SBx locations. Per region, the set of 19 computed parameters was further extended by derivation of eight radiomic features per parameter. Based on this feature set, a multiparametric ultrasound approach was implemented using five different classifiers together with a sequential floating forward selection method and hyperparameter tuning. The classification accuracy with respect to the biopsy reference was assessed by a group-k-fold cross-validation procedure, and the performance was evaluated by the Area Under the Receiver Operating Characteristics Curve (AUC). Of the 54 patients, 20 were found with clinically significant prostate cancer (csPCa) based on SBx. The 18 hemodynamic parameters showed mean AUC values varying from 0.63 to 0.75, and SWE elasticity showed an AUC of 0.66. The multiparametric approach using radiomic features derived from hemodynamic parameters only produced an AUC of 0.81, while the combination of hemodynamic and tissue-stiffness quantifications yielded a significantly improved AUC of 0.85 for csPCa detection (p -value < 0.05) using the Gradient Boosting classifier. Our results suggest 3D multiparametric ultrasound imaging combining hemodynamic and tissue-stiffness features to represent a promising diagnostic tool for biopsy outcome prediction, aiding in csPCa localization. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03015629
Volume :
50
Issue :
8
Database :
Academic Search Index
Journal :
Ultrasound in Medicine & Biology
Publication Type :
Academic Journal
Accession number :
177944660
Full Text :
https://doi.org/10.1016/j.ultrasmedbio.2024.04.007