Back to Search Start Over

Development and validation of LC-MS/MS method for trace analysis of acrylamide, acrylic acid and N, N-methylene bis acrylamide in sandy loam soil.

Authors :
Talaviya, Harshang
Singh, Anupama
Singh, Neera
Manna, Suman
Banerjee, Tirthankar
Source :
Journal of Chromatography A. Aug2024, Vol. 1729, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

• A method for quantifying AD, AA, and MBA in soil using LC-MS/MS. • The modified QuEChERS with addition of water enhances extraction recovery. • Method validated for specificity, linearity, sensitivity, accuracy, and precision. • The method LOQ for AD, AA, MBA in soil: 0.05, 1, 0.01 µg g–1. Acrylamide and N, N-methylene bis acrylamide are most commonly used monomer and crosslinker compounds employed in synthesis of super absorbent hydrogels. When applied as soil conditioners, there are apprehensions that these hydrogels degrade over time and thus may release the toxic monomers in the soil. A method was thus developed using Liquid Chromatography tandem mass spectrometry (LC-MS/MS) for the trace level quantification of acrylamide (AD), acrylic acid (AA) and N,N-methylene-bis-acrylamide (MBA) in sandy loam soil amended by two test hydrogels the Pusa Hydrogel and SPG 1118 hydrogel prepared using AD and MBA. The MRM (multiple reaction monitoring) transitions were optimized for both the compounds. Soil samples were extracted using dispersive solid-phase extraction (dSPE) with a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) technique, employing acetonitrile. All analytes were quantified at trace levels within a five-minute run using UHPLC equipped with a C-18 column. Single laboratory validation of the developed method in soil matrix was conducted based on specificity, linearity, sensitivity, accuracy, precision, matrix effect and measurement of uncertainty. LC-MS/MS exhibited a linear response in the concentration range of 0.001 to 1 µg mL−1, with correlation coefficient >+0.99. Acceptable recovery (within 70–120 %) with repeatability (%RSD ≤20 %) was obtained at 0.01 to 1 µg g–1 fortification levels. LOQ (Limit of quantification) of the method for AD, AA and MBA in soil matrix were 0.05, 1 and 0.01 µg g–1, respectively. Both intra-laboratory repeatability and intermediate precision at LOQ suggested well acceptable precise (HorRat≈ 0.3) method for quantification. Matrix enhancement effect was observed in the order: AA>AD>MBA. The Expanded Uncertainty (EU) in soil matrix at LOQ was 21.64 %, 28 % and 19 % for AD, AA and MBA respectively. Groundnut and wheat grown with application of the hydrogels showed no detectable residues of monomers in soil samples (total n = 60) near the root zone at the time of crop harvesting. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00219673
Volume :
1729
Database :
Academic Search Index
Journal :
Journal of Chromatography A
Publication Type :
Academic Journal
Accession number :
177881217
Full Text :
https://doi.org/10.1016/j.chroma.2024.465012