Back to Search Start Over

Increased water content in multifidus muscles of young adults with chronic nonspecific low back pain detected by dual-energy CT and MRI.

Authors :
Zhou, Xiaona
Liu, Yinqi
Chen, Suping
Xiang, Jian
Li, Jianying
Li, Jianyu
You, Tian
Zhong, Zeya
Zhang, Kun
Source :
European Journal of Radiology. Jul2024, Vol. 176, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

• The water content in paraspinal muscles may be assessed by Dual-energy CT and MRI T2-mapping. • T2 values in MRI has positive correlations with water density in DECT in paraspinal muscles. • Increased water content in paraspinal muscles in CNLBP was detected by DECT and MRI. To demonstrate the feasibility of better diagnosing young adults with chronic nonspecific low back pain (CNLBP) by measuring water content in paraspinal muscles using water-muscle decomposition technique in dual-energy CT (DECT) and T2-mapping in MRI. This prospective cross-sectional study included 110 young individuals (56 with CNLBP at age of 25.7 ± 2.0 years and 54 of asymptomatic at age of 25.1 ± 1.9 years) who underwent both MRI and DECT on the spine. T2 values on T2 mapping in MRI and water density (WD) value on water(muscle) images in DECT were generated at the L1-L4 levels for erector spinae muscle and L2-L5 for multifidus muscle. Pain duration time, Oswestry Disability Index (ODI), Visual Analogue Scale (VAS) were recorded for CNLBP patients. Difference of T2 value and WD between the two patient groups, and correlations between T2 value and WD, and T2 value and WD with clinical indicators were analyzed. Compared with asymptomatic participants, the mean WD of multifidus muscle at L4-L5 and mean T2 values of multifidus muscle at L5 were significantly higher in CNLBP patients (all P < 0.05). T2 values had moderate to strong positive correlations (r = 0.34–0.60, all P < 0.05) with DECT WD in CNLBP patients and healthy volunteers. There was a weak correlation between VAS and WD in L5-level multifidus muscle (r = 0.29, P < 0.05). The T2 values in MRI and WD in DECT are higher in multifidus muscles of lower vertebra levels for young CNLBP patients, and there exists positive correlation between WD and T2 values, providing useful information for diagnosing CNLBP. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0720048X
Volume :
176
Database :
Academic Search Index
Journal :
European Journal of Radiology
Publication Type :
Academic Journal
Accession number :
177879096
Full Text :
https://doi.org/10.1016/j.ejrad.2024.111515