Back to Search Start Over

Current Evidence for a New Surgical Technique for Scleral Fixation: The Implantation of a Carlevale Lens, a Systematic Review.

Authors :
Barbieri, Francesca
Maglionico, Maria Novella
Casini, Giamberto
Guidi, Gianluca
Figus, Michele
Posarelli, Chiara
Source :
Journal of Clinical Medicine. Jun2024, Vol. 13 Issue 11, p3287. 13p.
Publication Year :
2024

Abstract

Background: The Carlevale lens (FIL SSF, Soleko IOL Division, Italy) is a new lens for suture-less scleral fixation. This paper aimed to systematically review articles on this lens, the surgical techniques used for its implantation, complications and outcomes. Methods: This systematic review was performed following the PRISMA guidelines. The search string used was "Carlevale" AND "scleral fixation" from inception until March 2024. For completeness, either case-control studies, case reports or case series written in English were included. The authors used the Newcastle–Ottawa scale for the case-control studies and the JBI Critical Appraisal Checklist for case reports and case series. Results: Twenty-nine articles were included. Scleral fixation with Carlevale lens can be performed by creating scleral flaps or, alternatively, by using scleral pockets. The two sclerotomies must be diametrically opposed, and are preferably created by 25-gauge trocars. A pars plana vitrectomy should be performed every time, and the design of the lens should be suitable for self-anchoring to the sclera; the most accredited strategy to achieve this is to avoid scleral sutures. There were only a few intraoperative and postoperative complications reported; vitreous hemorrhages were the most frequent intraoperative events, while the most relevant postoperative complications were vitreous hemorrhages, cystoid macular oedema and transient variations in the intraocular pressure. Excellent results have been obtained in terms of BCVA, IOL centration and stability, mean intraocular pressure, postoperative spherical equivalent, separation between anterior and posterior chamber and the distance of the IOL from anterior chamber structures. Conclusions: The foldable hydrophilic design of the Carlevale lens has shown good effectiveness, IOL stability and few intra and post-operative complications. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20770383
Volume :
13
Issue :
11
Database :
Academic Search Index
Journal :
Journal of Clinical Medicine
Publication Type :
Academic Journal
Accession number :
177872528
Full Text :
https://doi.org/10.3390/jcm13113287