Back to Search Start Over

Graphene oxide-zinc oxide nanocomposite modified disposable electrodes for detection of uric acid in fetal bovine serum.

Authors :
Yildirim, Ayla
Maral, Meltem
Tugba Zaman, Buse
Bozoglu, Aysen
Demir, Cansu
Bakırdere, Sezgin
Erdem, Arzum
Source :
Journal of Electroanalytical Chemistry. Jul2024, Vol. 965, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

[Display omitted] • GO-ZnO nanocomposite modified electrode was designed as an electrochemical biosensor. • This biosensor was used for the electrochemical determination of uric acid. • To demonstrate applicability of the developed method in real samples, measurements were performed in fetal bovine serum. • The determination of uric acid was tested in the presence of different biomolecules such as ascorbic acid and glucose. Uric acid (UA) is the end product of purine metabolism, which is involved in many physiological processes in humans. This compound is produced daily in the human body and the excess is excreted in urine. For various reasons, uric acid in human serum that is lower or higher than the reference range causes some diseases such as liver diseases, nephritis, multiple sclerosis and diabetes. Hence, determination of UA at trace levels is very crucial. Here, a pencil graphite electrode (PGE) modified with graphene oxide-zinc oxide (GO-ZnO) nanocomposite was used to develop an electrochemical biosensor (GO-ZnO/PGE) for UA detection. The prepared GO-ZnO modified electrodes was characterized by scanning electron microscopy (SEM), Energy-Dispersive X-Ray Spectroscopy (EDX), Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV). It was revealed that the existence of ZnO in the GO-ZnO/PGE largely enhanced the surface area and increased its sensitivity for electrochemical sensing of analyte. The uric acid biosensor exhibited voltammetric peaks in the differential pulse voltammetry (DPV) measurements, allowing electrochemical detection of UA. The detection limit of UA was found to be 2.56 μM in buffer medium in the range of 10–100 µM UA. The detection limit of UA was found to be 4.76 μM in 1:1000 diluted FBS medium in the range of 10–100 µM of UA. The GO-ZnO/PGE provided the results in good reproducubility based on electrochemical measuruments while detecting UA. Furthermore, selectivity tests were also performed in FBS medium containing possible interferents such as ascorbic acid (AA) and Glucose (Glu), demonstrating the applicability of GO-ZnO modified electrodes. Sensitivity was calculated for phosphate-buffered saline (PBS) and fetal bovine serum (FBS) mediums and found to be 0.22 and 0.47 μA μg−1 mL cm−2, respectively, which validates the good sensitivity of the GO-ZnO/PGE electrodes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15726657
Volume :
965
Database :
Academic Search Index
Journal :
Journal of Electroanalytical Chemistry
Publication Type :
Academic Journal
Accession number :
177864871
Full Text :
https://doi.org/10.1016/j.jelechem.2024.118345