Development and performance evaluation of a high solar contribution resorption-compression cascade heat pump for cold climates.

Authors :
Jia, Teng
Dou, Pengbo
Chu, Peng
Dai, Yanjun
Markides, Christos N.
Source :
Energy. Sep2024, Vol. 302, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Absorption-resorption heat pumps (ARHPs) have great potential in utilizing low-temperature solar heat for efficient winter heating, but are limited by their weak adaptability to cold climates relative to absorption heat pumps (AHPs) and vapor compression heat pumps (VCHPs). In this work, a resorption-compression cascade system consisting of ARHP and VCHP subsystems is proposed and investigated, with the goal of achieving efficient winter heating with improved solar contribution in cold climates. Thermodynamic models of the two subsystems and of the whole cascade system are developed for system feasibility verification and performance evaluations. Feasible operation temperature and pressure conditions are identified in terms of internal subsystem matching. Based on these operation conditions, the primary energy ratio (PER) – which is a key performance evaluation index – is investigated over a range of solar fractions (f). The results show that for cases without solar contribution, the PER can be generally >0.95 under feasible operating conditions. In addition, the primary energy saving ratio (PESR) and heating capacity lift ratio (ε lift), as well as the heat source temperature (T h) and ambient temperature (T amb) restriction, are all investigated and compared to those of other, competing heating systems. The results show that the proposed system can reduce the T h demand to 69 °C (with a minimum T amb of −21 °C) and extend the operational T amb to −31 °C (with a minimum T h of 90 °C), while importantly achieving PESR > 0.20 and ε lift > 20 % under the above extreme conditions. Moreover, when integrating the system with solar heat with f > 43 %, the proposed solar-assisted system has a clear PER advantage over an equivalent VCHP system in the T amb range from −31 °C to 10 °C, highlighting the possibility of achieving higher solar contribution in cold climates. • A novel resorption-compression cascade heat pump system was proposed. • Performances were compared with those of the VCHP and subcooling coupled system. • Potential of high solar contribution to heating in cold climates was stressed. • The system could be operated in ambient above −31 °C with heat source over 90 °C. • The system with solar fraction over 43 % has advantage over the equivalent system. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03605442
Volume :
302
Database :
Academic Search Index
Journal :
Energy
Publication Type :
Academic Journal
Accession number :
177859213
Full Text :
https://doi.org/10.1016/j.energy.2024.131806