Back to Search Start Over

Assessment of large‐diameter and small‐diameter SoftK specialty contact lenses for early‐stage keratoconus.

Authors :
Gal, Eyal
Gispets, Joan
Zyroff, Meira
Netanya, Efrat
Gantz, Liat
Source :
Ophthalmic & Physiological Optics. Jul2024, Vol. 44 Issue 5, p884-893. 10p.
Publication Year :
2024

Abstract

Introduction: Soft contact lenses may be a good alternative for early‐stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). Methods: Patients with Amsler–Krumeich grades I or II KC were fitted with small‐diameter (14.2 or 14.8 mm) SoftK (SD‐SoftK, cc = 0.48 mm) and large‐diameter (17 mm) SoftK (LD‐SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli‐Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post‐hoc analysis. Results: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23–55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD‐SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD‐SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD‐SoftK lenses significantly improved 10VA compared with habitual and LD‐SoftK. SD‐SoftK also significantly improved CS compared with habitual, but not LD‐SoftK. LD‐SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 μ vs. 0.07 ± 0.13 μ) but not SD‐SoftK (0.04 ± 0.07 μ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD‐SoftK (N = 3) compared with LD‐SoftK (N = 8), and 75% of participants preferred SD‐SoftK lenses. Conclusion: SD‐SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD‐SoftK lenses. SD‐SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD‐SoftK lenses. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02755408
Volume :
44
Issue :
5
Database :
Academic Search Index
Journal :
Ophthalmic & Physiological Optics
Publication Type :
Academic Journal
Accession number :
177772545
Full Text :
https://doi.org/10.1111/opo.13331