Back to Search Start Over

Experimental study and semi-empirical model of a thermostatic expansion valve of a R290 direct-expansion solar heat pump.

Authors :
Luz, Arthur Pacheco
Diniz, Hélio Augusto Goulart
Duarte, Willian Moreira
Machado, Luiz
Source :
International Journal of Refrigeration. Jul2024, Vol. 163, p56-70. 15p.
Publication Year :
2024

Abstract

• The article introduces a novel semi-empirical model for a TEV operating with R290. • No prior experimental work was found involving TEV operating with R290 in DX-SAHP. • The article emphasizes a careful data collection process encompassing 150 experiments. • The multiple linear regression resulted in a R² of 0.9648 with predictions not exceeding more than 15 % deviation. • The model was applied and compared with 44 experiments from the literature, resulting in a deviation of less than 15 %. The expansion device plays a crucial role in the operation of heat pumps and refrigeration systems, making its study integral to advancements in the fields of refrigeration and heating. Among various expansion devices, the Thermostatic Expansion Valve (TEV) stands out due to its rapid response time and mechanical nature, which grants it high control capacity over refrigerant superheating. In this study, was developed a semiempirical mathematical model for a TEV incorporated in a DX-SAHP utilizing R290. The research was carried out in an experimental way, conducted using a fully instrumented DX-SAHP. A series of experiments tested different operational modes for water heating, subject to varying solar radiation intensities. A uniform methodology collected operational parameters, resulting in 150 experiments. The semiempirical model creation involved combining basic equations from the literature describing TEV operation and formulating an equation using multiple linear regression based on experimentally evaluated parameters. These parameters included solar radiation incidence, inlet and outlet pressures, and superheating degree. The regression model achieved an adjustment higher than 96 %. Combining this regression with equations suggested by previous researchers, resulted in a model with an adjustment exceeding 94 %. Furthermore, this study culminated in the derivation of a generalized model primed for broad application across various heat pump configurations for water heating purposes. Notably, the model underwent rigorous validation across a separate set of experiments, reaffirming its reliability and versatility. While excelling in steady-state operations, the model's transient data analysis falls short, as intended. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01407007
Volume :
163
Database :
Academic Search Index
Journal :
International Journal of Refrigeration
Publication Type :
Academic Journal
Accession number :
177391813
Full Text :