Calibration of simulation model to analyze hospital building energy performance.

Authors :
Harshalatha
Patil, Shantharam
Kini, Pradeep G.
Source :
Energy & Buildings. Jun2024, Vol. 313, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

• Utilizes EnergyPlus software to calibrate an energy simulation model for hospital in India. • Calibration parameters are systematically identified and adjusted through an iterative process. • The study highlights the need for a nuanced approach in modeling healthcare facilities. • Findings aim to foster sustainable hospital infrastructure in warm-humid climates. This research paper addresses the calibration of an energy simulation model for a naturally ventilated hospital building located in Mangalore, Karnataka, India, in a warm, humid climatic zone. The study aims to enhance the accuracy of energy consumption calculations through a calibration process by developing the energy model of a reference hospital building using EnergyPlus software. The required architectural design data, construction details, occupancy and schedule data and services are collected through documents, energy audits and documentation, measured drawings, and semi-structured interviews. Calibration parameters are systematically identified and adjusted through an iterative process. The monthly electricity bill is used to validate the simulation model. The simulation model reached during the validation process has an excellent Coefficient of Variation-Root Mean Squared Error of 4.24% and a Normalized Mean Bias Error of −4.42%, both of which meet the ASHRAE-approved accuracy standards. The paper also discusses the challenges and emphasizes the need for a nuanced approach to modeling healthcare facilities. Notwithstanding the challenges faced, the study offers insightful information about how to calibrate simulation models for hospital energy usage with the significant influence of scheduling for artificial lighting and equipment usage. By pioneering a manual calibration approach tailored to hospital simulation models in the warm humid climate of India, this paper offers a novel and practical solution to address the challenges of energy performance analysis in resource-constrained environments. The calibrated simulation model presented in this study is a valuable tool for assessing and improving the energy performance of naturally ventilated healthcare facilities. By creating alternative space layouts, the research findings aim to foster the development of hospital infrastructure that is both ecologically friendly and energy-efficient in a specific climatic context. This research is assured to make a substantial contribution to the advancement of sustainable hospital design in warm-humid climates, with implications for both academia and industry. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03787788
Volume :
313
Database :
Academic Search Index
Journal :
Energy & Buildings
Publication Type :
Academic Journal
Accession number :
177319633
Full Text :
https://doi.org/10.1016/j.enbuild.2024.114242