An Assessment of a Photovoltaic System's Performance Based on the Measurements of Electric Parameters under Changing External Conditions.
- Source :
-
Energies (19961073) . May2024, Vol. 17 Issue 9, p2197. 22p. - Publication Year :
- 2024
-
Abstract
- This article presents an analysis of the performance of a 14.04 kWp grid-connected photovoltaic (PV) installation consisting of monocrystalline silicon, polycrystalline silicon and bifacial glass–glass monocrystalline silicon modules. The photovoltaic system was mounted in Poland, a location characterized by temperate climate conditions. On the basis of the obtained results, the photovoltaic parameters were determined in accordance with the international standard. The annual energy yield of the entire system was 1033 kWh/kWp, and the performance ratio achieved was 83%. The highest average daily final yield was in the range of 4.0–4.5 kWh/kWp for each photovoltaic technology under investigation. In the cold part of the year, the efficiency of the photovoltaic modules was estimated to be 15%, and it was estimated to be 7% during the warm part of the year. Array capture losses accounted for around 0.75 kWh/kWp of energy loss per day, whereas the inverter efficiency was over 95% during the months that are beneficial for energy production. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 19961073
- Volume :
- 17
- Issue :
- 9
- Database :
- Academic Search Index
- Journal :
- Energies (19961073)
- Publication Type :
- Academic Journal
- Accession number :
- 177181942
- Full Text :
- https://doi.org/10.3390/en17092197