Back to Search
Start Over
Robot-Assisted Radical Prostatectomy Performed with the Novel Surgical Robotic Platform Hugo™ RAS: Monocentric First Series of 132 Cases Reporting Surgical, and Early Functional and Oncological Outcomes at a Tertiary Referral Robotic Center.
- Source :
-
Cancers . Apr2024, Vol. 16 Issue 8, p1602. 11p. - Publication Year :
- 2024
-
Abstract
- Simple Summary: New devices are being developed and proliferated worldwide to perform robotic surgery. The sharing of data resulting from performing a large number of procedures with the HugoTM RAS system aims to demonstrate its reliability and potential use in different scenarios. In our case series, this new device has proven to be reliable in performing robot-assisted radical prostatectomy. We list the solutions we applied to address the technical issues of the system and show that these did not have a significant impact on patients and procedures. Background: Robotic-assisted surgery is the gold standard for performing radical prostatectomy (RARP), with new robotic devices such as HugoTM RAS gaining prominence worldwide. Objective: We report the surgical, perioperative, and early postoperative outcomes of RARP using HugoTM RAS. Design, setting, and participants: Between April 2022 and October 2023, we performed 132 procedures using the Montsouris technique with a four-robotic-arm configuration in patients with biopsy-proven prostate cancer (PCa). Outcome measures: We collected intraoperative and perioperative data during hospitalization, along with follow-up data at predefined postoperative intervals of 3 and 6 months. Results and limitations: Lymphadenectomy was performed in 25 procedures, with a bilateral nerve-sparing technique in 33 and a monolateral nerve-sparing technique in 33 cases. The mean total surgery time was 242 (±57) min, the mean console time was 124 (±48) min, and the mean docking time was 10 (±2) min. We identified 17 system errors related to robotic arm failures, 9 robotic instrument breakdowns, and 8 significant conflicts between robotic arms. One post-operative complication was classified as Clavien–Dindo 3b. None of the adverse events, whether singular or combined, increased the operative time. Positive margins (pR1) were found in 54 (40.9%) histological specimens, 37 (28.0%) of which were clinically significant. At 3 and 6 months post-surgery, the PSA levels were undetectable in 94.6% and 92.1% of patients, respectively. Social urinary continence was regained in 86% after 6 months. Limitations of our study include its observational monocentric case-series design and the short follow-up data for functional and oncological outcomes. Conclusions: Our initial experience highlights the reliability of the HugoTM RAS system in performing RARP. Additionally, we also list problems and solutions found in our daily work. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 20726694
- Volume :
- 16
- Issue :
- 8
- Database :
- Academic Search Index
- Journal :
- Cancers
- Publication Type :
- Academic Journal
- Accession number :
- 176877018
- Full Text :
- https://doi.org/10.3390/cancers16081602