Back to Search Start Over

Adjustable chromatographic performance of silica-based mixed-mode stationary phase through the control of co-grafting amounts of imidazole and C18 chain.

Authors :
Yang, Yali
Chen, Jia
Liang, Xiaojing
Liu, Bei
Quan, Kaijun
Liu, Xiuhui
Qiu, Hongdeng
Source :
Journal of Chromatography A. May2024, Vol. 1722, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

• Three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared. • Chromatographic performance can be adjusted by the control of different co-grafting amounts of C18 chain and imidazole group. • The prepared stationary phases can be used in reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC). • Excellent separation performance for PAHs, phenylesters, phenylamines, phenols and inorganic anions was obtained. • Nucleobases and nucleosides can be separated using pure water as mobile phases. In this paper, three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared by adjusting introduction interval of octadecyltrichlorosilane (ODS) and 3-imidazol-1-ylpropyl(trimethoxy)silane (TMPImS), which can be used for reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC) with adjustable performance. The successful preparation of Sil-Im-C18 were confirmed by the characterizations of elemental analysis, infrared spectroscopy (FTIR) and contact angle (CA). Chromatographic performance of Sil-Im-C18 were evaluated by the separation of Tanaka test mixture, alkylbenzenes, linear PAHs and a set of analytes with different properties (uracil, phenol, 1,2-dinitrobenzene and naphthalene), and compared with commonly used C18 column. It was found that the chromatographic performance of Sil-Im-C18 changed significantly with the difference in bonding amount of imidazole and C18. Sil-Im-C18 demonstrated the excellent separation performance towards polycyclic aromatic hydrocarbons (PAHs), phenylesters, phenylamines, phenols and inorganic anions, and notably, nucleobases and nucleosides can be separated using pure water as mobile phases. The van Deemter plot showed that the column efficiency of Sil-Im-C18-3 was 64,933 plate· m −1 for naphthalene, indicated that Sil-Im-C18 was reasonably chromatographic columns. The RSD values of retention time were 0.22 %-0.61 % for 10 needles alkylbenzenes injected continuously at 50 °C to investigate thermal stability and repeatability, all the fluctuations of k of naphthalene were less than 2.3 % for Sil-Im-C18-1 during flushing 24 h with the mobile phase at different pH values (pH = 3 and 8), the retention time of alkylbenzenes were almost same for Sil-Im-C18-1 at different time, the RSD values of retention time of alkylbenzenes were 0.45 %-2.28 % for two batches Sil-Im-C18-1, revealing the excellent repeatability, thermal stability, durability and reproducibility of Sil-Im-C18, and implying a commercial prospect. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00219673
Volume :
1722
Database :
Academic Search Index
Journal :
Journal of Chromatography A
Publication Type :
Academic Journal
Accession number :
176784846
Full Text :
https://doi.org/10.1016/j.chroma.2024.464889