Experimental study of the natural convection characteristics of finned-tube sodium-to-air heat exchanger.
- Source :
-
Journal of Mechanical Science & Technology . Apr2024, Vol. 38 Issue 4, p2055-2062. 8p. - Publication Year :
- 2024
-
Abstract
- The finned-tube sodium-to-air heat exchanger plays a crucial role in ensuring the safety of prototype Gen IV sodium-cooled fast reactors. It is designed to actively operate with power, but it is also important to consider its passive performance to ensure availability during power-out conditions. This study focused on addressing this limitation through a natural convection experiment using a dedicated facility, and the obtained results were compared with the safety analysis code MARS-LMR. The overall temperature difference was observed to be within an acceptable range of less than 5 %. While the code calculations aligned well with the experimental results at higher temperatures, they underestimated the experimental results at lower temperatures. These findings can serve as a basis for other codes employing different heat transfer correlations and for future reactor licensing purposes. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 1738494X
- Volume :
- 38
- Issue :
- 4
- Database :
- Academic Search Index
- Journal :
- Journal of Mechanical Science & Technology
- Publication Type :
- Academic Journal
- Accession number :
- 176727638
- Full Text :
- https://doi.org/10.1007/s12206-024-0335-2