Back to Search Start Over

Quantitative assessment of left ventricular myocardial work in patients with different types of atrial fibrillation by non‐invasive pressure‐strain loop technique.

Authors :
Liu, Tingting
Liu, Hailan
Song, Yan
Huang, Yulin
Zhang, Chunquan
Source :
Echocardiography. Mar2024, Vol. 41 Issue 3, p1-10. 10p.
Publication Year :
2024

Abstract

Objective: This study aimed to analyze myocardial work in patients with atrial fibrillation (AF) using a noninvasive pressure strain loop (PSL) technique to provide a basis for the quantitative assessment of left ventricular (LV) systolic function. Methods: LV myocardial work of 107 AF patients (56 with paroxysmal atrial fibrillation and 51 with persistent atrial fibrillation) and 55 healthy individuals were assessed by the noninvasive PSL and then compared. Results: Global longitudinal strain (GLS) in absolute values, global work index (GWI), global constructive work (GCW), and global work efficiency (GWE) were significantly lower in the AF group than control group, whereas peak strain dispersion (PSD) and global wasted work (GWW) were significantly higher (P <.05). Further subdivision according to the AF type revealed that, compared with the controls, GLS in absolute values and GWE decreased significantly; PSD and GWW increased significantly in the paroxysmal AF group (P <.05). Nevertheless, GWI and GCW were not significantly different between paroxysmal AF and control groups (P >.05). Compared to paroxysmal AF, persistent AF induced a further decrease in absolute GLS and GWE and a further increase in GWW (P <.05), but PSD did not increase further (P >.05). Multiple linear regression analysis showed that GWI and GCW were independently associated with systolic blood pressure. GWW was associated with types of AF and left atrial volume index (LAVI). GWE was correlated with age, types of AF, disease duration, and LAVI. Receiver operating characteristic curve analysis showed that the area under the curve predicting myocardial injury was higher for GWE and GWW than for GLS (area under the curve:.880,.846, and.821, respectively). Conclusions: Non‐invasive PSL can quantitatively assess LV systolic function in patients with different kinds of AF and detect early subclinical myocardial injury in patients with paroxysmal AF. GWE and GWW outperform GLS and LV ejection fraction when assessing myocardial injury. Systolic blood pressure, type of AF, LVAI, disease duration, and age may be associated with myocardial injury in patients with AF. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07422822
Volume :
41
Issue :
3
Database :
Academic Search Index
Journal :
Echocardiography
Publication Type :
Academic Journal
Accession number :
176274016
Full Text :
https://doi.org/10.1111/echo.15801