Back to Search Start Over

Shaking table test study on the seismic control of concrete-filled steel tube arch bridges based on dampers.

Authors :
Li, Yong
Song, Cheng
Song, Linlin
Zhao, Xiaosha
Guan, Zhongzheng
Wang, Yichao
Source :
Archives of Civil & Mechanical Engineering (Elsevier Science). Apr2024, Vol. 24 Issue 2, p1-23. 23p.
Publication Year :
2024

Abstract

Concrete-filled steel tube (CFST) arch bridges have a high center of gravity and a substantial mass, resulting in a discernible seismic response. Consequently, long-span CFST arch bridges must retain exceptional seismic performance and appropriate seismic control design. In this study, the dynamic response and seismic performance of a unique swallow-type CFST arch bridge when subjected to longitudinal earthquake forces were analyzed using numerical simulation methods. The displacement and axial force response results and their laws of the key bridge components were obtained. Taking into account seismic checking calculations, two damping measures were proposed for the CFST arch bridge, as the relative displacement of the girder end exceeded the allowable value specified. The appropriate design parameters for viscous dampers and lead shear dampers were examined. Additionally, the seismic performance of these dampers was verified through a shaking table test using a 1:16 scale model. The findings indicated that when subjected to Wenchuan Wolong wave action, the relative displacement between the steel box girder and the concrete girder of the bridge was significantly larger, leading to girder end pounding. The limit values were surpassed by 32.5% and 50%, when subjected to the uniform and traveling wave excitations, respectively, thus indicating that the expansion joint was the most vulnerable component. Following the selection of optimal parameters for the dampers, the dampers exhibited the capability to mitigate seismic and pounding impacts. Long-span CFST arch bridges with dampers were found to effectively reduce the seismic response of the skewback strain and vault, as well as the relative displacement of the girder ends. Furthermore, the average maximum damping rates achieved by the viscous damper and the lead shear damper reached 44.9% and 44.6%, respectively. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16449665
Volume :
24
Issue :
2
Database :
Academic Search Index
Journal :
Archives of Civil & Mechanical Engineering (Elsevier Science)
Publication Type :
Academic Journal
Accession number :
176082216
Full Text :