Back to Search Start Over

Development and validation of an artificial intelligence assisted prenatal ultrasonography screening system for trainees.

Authors :
Lei, Ting
Feng, Jie Ling
Lin, Mei Fang
Xie, Bai Hong
Zhou, Qian
Wang, Nan
Zheng, Qiao
Yang, Yan Dong
Guo, Hong Mei
Xie, Hong Ning
Source :
International Journal of Gynecology & Obstetrics. Apr2024, Vol. 165 Issue 1, p306-317. 12p.
Publication Year :
2024

Abstract

Objective: Fetal anomaly screening via ultrasonography, which involves capturing and interpreting standard views, is highly challenging for inexperienced operators. We aimed to develop and validate a prenatal‐screening artificial intelligence system (PSAIS) for real‐time evaluation of the quality of anatomical images, indicating existing and missing structures. Methods: Still ultrasonographic images obtained from fetuses of 18–32 weeks of gestation between 2017 and 2018 were used to develop PSAIS based on YOLOv3 with global (anatomic site) and local (structures) feature extraction that could evaluate the image quality and indicate existing and missing structures in the fetal anatomical images. The performance of the PSAIS in recognizing 19 standard views was evaluated using retrospective real‐world fetal scan video validation datasets from four hospitals. We stratified sampled frames (standard, similar‐to‐standard, and background views at approximately 1:1:1) for experts to blindly verify the results. Results: The PSAIS was trained using 134 696 images and validated using 836 videos with 12 697 images. For internal and external validations, the multiclass macro‐average areas under the receiver operating characteristic curve were 0.943 (95% confidence interval [CI], 0.815–1.000) and 0.958 (0.864–1.000); the micro‐average areas were 0.974 (0.970–0.979) and 0.973 (0.965–0.981), respectively. For similar‐to‐standard views, the PSAIS accurately labeled 90.9% (90.0%–91.4%) with key structures and indicated missing structures. Conclusions: An artificial intelligence system developed to assist trainees in fetal anomaly screening demonstrated high agreement with experts in standard view identification. Synopsis: An artificial intelligence system developed for trainees showed high agreement with experts in identifying standard view, which may promote novice operators to obtain diagnostic images. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00207292
Volume :
165
Issue :
1
Database :
Academic Search Index
Journal :
International Journal of Gynecology & Obstetrics
Publication Type :
Academic Journal
Accession number :
176077595
Full Text :
https://doi.org/10.1002/ijgo.15167