Back to Search Start Over

A novel versatile concept of cardioplegia delivery in cardiac surgery: The ReverseTWO cardioplegia circuit system.

Authors :
Colangelo, Nicola
Sala, Alessandra
Gallio, Giulia
Blasio, Andrea
De Simone, Francesco
Aina, Alessandro
Buffa, Antonino
Verzini, Alessandro
Alfieri, Ottavio
Maisano, Francesco
Castiglioni, Alessandro
De Bonis, Michele
Source :
Perfusion. Apr2024, Vol. 39 Issue 3, p473-478. 6p.
Publication Year :
2024

Abstract

Nowadays, the necessity of having a cardioplegia circuit capable of being adapted in order to administer different types of cardioplegia is strategically fundamental, both for the perfusionist and for the cardiac surgeon. This allows to avoid cutting tubes, guarantees sterility and, most of all, limits the number of cardioplegia circuits for the different strategies of cardiac arrest. The novel "ReverseTWO cardioplegia circuit system" is the development of the precedent "Reverse system" where mainly the 4:1 and crystalloid cardioplegia were used, It has the advantage of allowing immediate change of cardioplegia set-up versus four types of cardioplegia technique, when the strategy is unexpectedly changed before the beginning of cardiopulmonary bypass (CPB), is safe and enables the perfusionist to use one single custom pack of cardioplegia. Two pediatric roller pumps are usually used in our centre for cardioplegia administration; they have a standardized calibration (the leading with ¼ inch and the follower with 1/8 inch) and the circuit consequently has two different tube diameters for the two different pumps. The presence in the circuit of two different shunts coupled with two different coloured clamps allows the immediate set-up for different cardioplegia administration techniques utilizing a colour-coding mechanism The aim of this manuscript is to present the new ReverseTWO Circuit. This novel system allows to administer four different cardioplegic solutions (4:1, 1:4, crystalloid, ematic) based on multiple tubes, which can be selectively clamped, identified through a color-coding method. The specificity of this circuit is the great versatility, which leads to numerous advantages, such as reduced risk of perfusion accident and reduced costs related not only to the purchase of different cardioplegia kits but also to the storage. https://youtu.be/ovJBE4ok2Ds [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02676591
Volume :
39
Issue :
3
Database :
Academic Search Index
Journal :
Perfusion
Publication Type :
Academic Journal
Accession number :
176064949
Full Text :
https://doi.org/10.1177/02676591221150168