Back to Search Start Over

Efficacy and safety between radiofrequency ablation and types of cryoablation catheters for atrioventricular nodal reentrant tachycardia: A Network Meta‐analysis and Systematic Review.

Authors :
Siranart, Noppachai
Keawkanha, Ponthakorn
Pajareya, Patavee
Chokesuwattanaskul, Ronpichai
Ayudhya, Choutchung Tinakorn Na
Prasitlumkum, Narut
Chung, Eugene H
Jongnarangsin, Krit
Tokavanich, Nithi
Source :
Pacing & Clinical Electrophysiology. Mar2024, Vol. 47 Issue 3, p353-364. 12p.
Publication Year :
2024

Abstract

Introduction: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia referred for ablation. Periprocedural conduction system damage was a primary concern during AVNRT ablation. This study aimed to assess the incidence of permanent atrioventricular (AV) block and the success rate associated with different types of catheters in slow pathway ablation. Method: A literature search was performed to identify studies that compared various techniques, including types of radiofrequency ablation (irrigated and nonirrigated) and different sizes of catheter tip cryoablation (4, 6, and 8‐mm), in terms of their outcomes related to permanent atrioventricular block and success rate. To assess and rank the treatments for the different outcomes, a random‐effects model of network meta‐analysis, along with p‐scores, was employed. Results: A total of 27 studies with 5110 patients were included in the analysis. Overall success rates ranged from 89.78% to 100%. Point estimation showed 4‐mm cryoablation exhibited an odds ratio of 0.649 (95%CI: 0.202–2.087) when compared to nonirrigated RFA. Similarly, 6‐mm cryoablation had an odds ratio of 0.944 (95%CI: 0.307–2.905), 8‐mm cryoablation had an odds ratio of 0.848 (95%CI: 0.089–8.107), and irrigated RFA had an odds ratio of 0.424 (95%CI: 0.058–3.121) compared to nonirrigated RFA. Conclusion: Our study found no significant difference in the incidence of permanent AV block between the types of catheters. The success rates were consistently high across all groups. These findings emphasize the potential of both RF ablation (irrigated and nonirrigated catheter) and cryoablation as viable options for the treatment of AVNRT, with similar safety and efficacy profile. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01478389
Volume :
47
Issue :
3
Database :
Academic Search Index
Journal :
Pacing & Clinical Electrophysiology
Publication Type :
Academic Journal
Accession number :
175965431
Full Text :
https://doi.org/10.1111/pace.14915