Back to Search Start Over

Assessment of the synthetic inertial response of an actual solar PV power plant.

Authors :
Villena-Ruiz, Raquel
Honrubia-Escribano, Andrés
Hernández, Jesús C.
Gómez-Lázaro, Emilio
Source :
International Journal of Electrical Power & Energy Systems. Jun2024, Vol. 157, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

• Pioneer Spain: first country to include in grid code the synthetic inertia capability. • Synthetic inertial response of a PV inverter studied based on the Spanish grid code. • Analyzed the role of power plant controller in the dynamic response of the facility. • PV system able to contribute to frequency control providing an inertial response. As the large-scale integration of renewable energy grows, inertia in power systems is reduced, which causes the rate of change of frequency to increase and worsens the frequency nadir during disturbances. There is, therefore, an urgent need to accelerate the development of international standards and regulations that require solar PV systems and other renewable installations to also contribute to stability in the network by emulating inertia. Spain is a pioneer in this field: it is currently the only country that includes the synthetic inertia technical requirement in its grid code. In this context, the present paper analyzes the synthetic inertial response of a PV system model that forms part of an actual PV power plant in Spain under two scenarios, according to its grid code: i) when measurements are conducted at the power conversion PV system level and hence only its control algorithms are executed; and ii) when measurements are conducted at the power plant level and the power plant controller also influences the response of the entire installation. Among its aims, this paper seeks to thoroughly assess the response of an actual PV power conversion system that has the capability of actively contributing to frequency regulation in a network and to critically analyze the suitability of having a power plant controller when the PV facility contributes to power-frequency control by means of an inertial response. The results reveal, at the power conversion PV system level, that the inertia emulation module significantly reduces the response times of the installation to changes in frequency -by more than 68% in the worst case under frequency increases, and by 73% under frequency decreases, thus contributing to more rapid power-frequency regulation in the network. However, at the power plant level, the power plant controller disturbs the PV power conversion system's behavior and causes the opposite effect: response times increase -up to more than 7% in the most unfavorable case when the inertia module is enabled. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01420615
Volume :
157
Database :
Academic Search Index
Journal :
International Journal of Electrical Power & Energy Systems
Publication Type :
Academic Journal
Accession number :
175937274
Full Text :
https://doi.org/10.1016/j.ijepes.2024.109875