Back to Search Start Over

Virtual three-dimensional kinematics comparison between normal healthy knee and tumor-suffered knee post resection with mega prosthesis reconstructed.

Authors :
Ardianov, Mohamad Fadhil
Prabowo, Yogi
Supriadi, Sugeng
Mathar, Pelangi Raihan
Kamal, Achmad Fauzi
Source :
AIP Conference Proceedings. 2024, Vol. 3080 Issue 1, p1-9. 9p.
Publication Year :
2024

Abstract

In this study, two novel designs of Modular Mega prosthesis (MDF 1 and MDF 2) are generated with different geometries and dimensions, with a reference to a normal knee Modular Prosthesis emerging as one of the most promising alternatives to replace the outdated amputation procedures for bone cancer treatment. To obtain a prosthesis with full flexion ability, a better understanding of normal and healthy knees is needed. To replicate knee movements, 3–axis simulations to acquire interference between femoral condyles and the tibial base is applied to both designs and normal knee to better compare the range of movements. Volume interference as an indicator of high - flexion in knee rotation movements is established. The result showed that MDF 2 can give a superior result of flexion-extension rotations compared to normal knees and MDF 1. The range of movement in internal-external and varus-valgus rotations of normal knees is still higher than both MDF 1 and MDF 2, although the results of movement for both novel designs are not too distinctive. The simulations in this study showed that both designs, MDF 1 and MDF 2 have great potential as a solution after limb-salvage resection. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
3080
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
175915190
Full Text :
https://doi.org/10.1063/5.0199160