Back to Search Start Over

The ground fault detection system for the Tore Supra toroidal pump limiter

Authors :
Zunino, K.
Cara, P.
Fejoz, P.
Hourtoule, J.
Loarer, T.
Pomaro, N.
Santagiustina, A.
Spuig, P.
Villecroze, F.
Source :
Fusion Engineering & Design. Aug2003, Vol. 66-68, p1019-1023. 5p.
Publication Year :
2003

Abstract

The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
09203796
Volume :
66-68
Database :
Academic Search Index
Journal :
Fusion Engineering & Design
Publication Type :
Academic Journal
Accession number :
17579025
Full Text :
https://doi.org/10.1016/S0920-3796(03)00253-9