Back to Search
Start Over
Thoracic-Worn Accelerometers Detect Fatigue-Related Changes in Vertical Stiffness During Sprinting.
- Source :
-
Journal of Strength & Conditioning Research . Feb2024, Vol. 38 Issue 2, p283-289. 7p. - Publication Year :
- 2024
-
Abstract
- Horsley, BJ, Tofari, PJ, Halson, SL, Kemp, JG, Johnston, RD, and Cormack, SJ. Thoracic-worn accelerometers detect fatiguerelated changes in vertical stiffness during sprinting. J Strength Cond Res 38(2): 283-289, 2024--Thoracic-mounted accelerometers are valid and reliable for analyzing gait characteristics and may provide the opportunity to assess running-related neuromuscular fatigue (NMF) during training and competition without the need for additional tests, such as a countermovement jump (CMJ). However, their sensitivity for detecting fatigue-related changes in gait across different speeds is unclear. We, therefore, assessed the changes in accelerometer-derived gait characteristics, including vertical stiffness (Kvert), following a repeated sprint protocol (RSP). Sixteen recreationally active subjects performed single and repeated CMJs on a force plate and 40 m run throughs overground at 3-4, 5-6, and 7-8 m·s21 pre-post a 123 40 mRSP. Gait characteristics (contact time, step frequency, step length, Kvert, etc.) were derived from an accelerometer contained within a global navigation satellite system unit on the thoracic spine using a validated algorithm. Changes in running gait and CMJ performance were assessed using a linear mixed-effects model (95% confidence interval [95% CI]; effect size [ES]). Significance was set at p < 0.05. A significant reduction in Kvert occurred at 7-8m·s21 following the RSP (28.51 kN·m21 [213.9, 23.11]; p 5 0.007; ES [95% CI] 5 20.39 [20.62, 20.15]) which coincided with a decreased jump height (20.03 m [20.04, 20.01]; p 5 0.002; ES [95% CI] 5 20.87 [21.41, 20.30]). However, all other gait characteristics were not significantly different irrespective of speed. Thoracic-worn accelerometers can detect changes in Kvert at 7-8 m·s21 which may be useful for monitoring NMF during sprinting. However, a RSP does not result in altered gait mechanics in subsequent running at lower speeds. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10648011
- Volume :
- 38
- Issue :
- 2
- Database :
- Academic Search Index
- Journal :
- Journal of Strength & Conditioning Research
- Publication Type :
- Academic Journal
- Accession number :
- 175563500
- Full Text :
- https://doi.org/10.1519/jsc.0000000000004614