Back to Search Start Over

Development of a competitive immunoassay for the determination of N-(2-hydroxypropyl)valine adducts in human haemoglobin and its application in biological monitoring.

Authors :
Ball, L.
Jones, A.
Boogaard, P.
Will, W.
Aston, P.
Source :
Biomarkers. Mar-Jun2005, Vol. 10 Issue 2/3, p127-137. 11p.
Publication Year :
2005

Abstract

Propylene oxide (PO) is an important industrial compound and a directly acting mutagen. Human exposure to PO can be monitored by the determination of haemoglobin adducts. An immunoassay that quantifies the N-terminal adduct N-(2-hydroxypropyl)valine in whole haemoglobin was developed and its potential usefulness as a tool for biologically monitoring occupational exposure was demonstrated. Analytical reliability was confirmed in a comparative study with GC-MS (range 3.7–992 nmol g -1 haemoglobin (Hb), correlation coefficient 0.99, n =10). The assay has been configured as a competitive enzyme-linked immunosorbent assay to facilitate the rapid throughput of samples. The assay employs a whole blood matrix and has a working range of 2–250 pmol g -1 Hb. It does not appear to be affected by structurally similar metabolites and has been used to determine adducts in human blood samples. The first results in potentially exposed workers indicate the assay's high potential usefulness in routine occupational biomonitoring of exposure to PO. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1354750X
Volume :
10
Issue :
2/3
Database :
Academic Search Index
Journal :
Biomarkers
Publication Type :
Academic Journal
Accession number :
17549465
Full Text :
https://doi.org/10.1080/13547500500158938