Back to Search
Start Over
Numerical Simulation of Electroosmotic Sutterby Hybrid Nanofluid Flowing Through an Irregularly Mild Stenotic Artery with an Aneurysm.
- Source :
-
Arabian Journal for Science & Engineering (Springer Science & Business Media B.V. ) . Feb2024, Vol. 49 Issue 2, p2483-2498. 16p. - Publication Year :
- 2024
-
Abstract
- Recently, aortic valve stenosis has received more attention, and its pathophysiology may be connected to persistent inflammation caused by micro-organisms. This paper investigates the transient electroosmotic hybrid nanofluid (blood model) flow in the annular region between the axially symmetric mild stenosis and the catheter tube. The non-Newtonian Sutterby fluid has been considered as a blood model due to the migration of gyrotactic micro-organisms in the bloodstream. The hybrid nanofluid consists of the suspension of the solid nanoparticles of the (Ag–Al 2 O 3 ) in pure human blood. The problem is simplified using the mild stenosis procedure and solved numerically utilizing the finite difference technique. It is observed that more effort is required to pump the blood in the case of the suspended hybrid nanoparticles than with suspended nanoparticles. Moreover, the results demonstrate that hybrid nanoparticles have better thermal properties than nanoparticles. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 2193567X
- Volume :
- 49
- Issue :
- 2
- Database :
- Academic Search Index
- Journal :
- Arabian Journal for Science & Engineering (Springer Science & Business Media B.V. )
- Publication Type :
- Academic Journal
- Accession number :
- 175359862
- Full Text :
- https://doi.org/10.1007/s13369-023-08257-y