Back to Search Start Over

Correction of creatine-creatinine conversion during serum creatinine quantification by two-dimensional liquid chromatography and double-spike isotope dilution tandem mass spectrometry.

Authors :
Pineda-Cevallos, Daniela
Funes Menéndez, María
González-Gago, Adriana
Rodríguez-González, Pablo
Ignacio García Alonso, J.
Source :
Clinica Chimica Acta. Feb2024, Vol. 554, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

• Development of a candidate reference method for serum creatinine determination correcting creatine-creatinine interconversion. • Two-dimensional liquid chromatography coupling reversed phase and cation exchange separation minimises matrix effects. • Quantification is carried out by multiple linear regression and double spiking isotope dilution tandem mass spectrometry. • Creatine-creatinine interconversion during sample preparation was evaluated with the analysis of 93 serum samples. • Negligible creatine-creatinine interconversion was found in all the analysed samples using the proposed sample preparation. Development of a candidate reference method based on bidimensional liquid chromatography coupled to ESI-MS/MS and double spike isotope dilution for serum creatinine quantification capable of correcting for creatinine-creatine interconversion during sample pretreatment. Study of the impact of the creatine-creatinine interconversion during the analysis of human serum samples. 13C 1 -creatinine and 13C 2 -creatine are added to the serum sample. Separation carried out by bidimensional liquid chromatography combining reversed phase and a strong cation exchange chromatography. The heart cut, containing creatine and creatinine, is automatically transferred to the second dimension. Quantification carried out by double spike isotope dilution tandem MS/MS. Minimization of spectral interferences and ion suppression due to matrix effects while increasing sample throughput compared to the direct coupling of cation exchange chromatography to the ESI source. Trueness of the method studied with the satisfactory analysis of two certified reference materials. Satisfactory intra- and inter-day precisions obtained analysing a serum pool and control sera. Analysis of 93 serum samples revealed negligible interconversions with no correlation with creatine levels. The method provides adequate analytical figures of merit for serum creatinine determination according to CSLI guidelines. Negligible creatine-creatinine interconversion is promoted with the applied sample preparation procedure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00098981
Volume :
554
Database :
Academic Search Index
Journal :
Clinica Chimica Acta
Publication Type :
Academic Journal
Accession number :
175191252
Full Text :
https://doi.org/10.1016/j.cca.2024.117778