Back to Search Start Over

Implementation and assessment of an electronic clinical decision support tool to notify clinicians of critical hyperbilirubinemia in preterm neonates less than 35 weeks' gestation.

Authors :
Xiao, Yi
Palmucc, Mandy
Carlin, Lance
Lee, Catherine
O'Gorman, Maurice R G
Nair, Srikumar
Yieh, Leah
Leung, Edward Ki-Yun
Source :
American Journal of Clinical Pathology. Jan2024, Vol. 161 Issue 1, p83-88. 6p.
Publication Year :
2024

Abstract

Objectives Critical hyperbilirubinemia in preterm neonates, a condition requiring greater attention, is treated with phototherapy or exchange transfusion when bilirubin results exceed gestational age and age-specific medical decision levels (MDLs) to prevent bilirubin-induced neurologic damage. Conventional evaluation involves multiple manual steps and is poised to inconsistencies and delays. Methods We designed and implemented an electronic clinical decision support (CDS) tool to identify and alert neonatal intensive care unit clinicians of critical hyperbilirubinemia with a SmartZone alert. We evaluated the performance of our manual evaluation workflow, the accuracy of the electronic CDS tool, and the outcome of the electronic CDS tool to reduce the time to place orders for interventions. Results Among the 22 patients who met the criteria to have phototherapy ordered before implementing the electronic CDS tool, 20 (90%) had phototherapy ordered. Fourteen (70%) phototherapy orders were placed less than 24 hours, 4 phototherapy orders were placed 24 to 72 hours, and 2 orders were placed more than 72 hours after bilirubin results exceeded the corresponding MDLs. Among the 15 patients who met the criteria to have phototherapy ordered after implementing the electronic CDS tool, all (100%) received phototherapy orders, with 14 (93%) placed less than 24 hours and 1 order placed less than 48 hours. The electronic CDS tool identified all eligible patients correctly. The proportion of phototherapy ordered less than 24 hours increased from 70% to 93% after the implementation of the electronic CDS tool. Conclusions The electronic CDS tool promoted more appropriate and timely intervention orders to manage critical hyperbilirubinemia in preterm neonates. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00029173
Volume :
161
Issue :
1
Database :
Academic Search Index
Journal :
American Journal of Clinical Pathology
Publication Type :
Academic Journal
Accession number :
174980185
Full Text :
https://doi.org/10.1093/ajcp/aqad112