Back to Search Start Over

Performance and reliability assessment of a lower dose, task-based scoliosis radiography protocol in pediatric patients.

Authors :
Al-Dasuqi, Khalid
Taylor, Erin
Ehrlich, Lauren
Cooperman, Daniel
Socci, Adrienne
Tuason, Dominick
Hoerner, Matthew
Staib, Lawrence
Silva, Cicero T.
Source :
Pediatric Radiology. Jan2024, Vol. 54 Issue 1, p146-153. 8p.
Publication Year :
2024

Abstract

Background: Follow-up scoliosis radiographs are performed to assess the degree of spinal curvature and skeletal maturity, which can be done at lower radiation exposures than those in standard-dose radiography. Objective: Describe and evaluate a protocol that reduced the radiation in follow-up frontal-view scoliosis radiographs. Materials and methods: We implemented a postero-anterior lower dose modified-technique for scoliosis radiography with task-based definition of adequate image quality and use of technique charts based on target exposure index and patient's height and weight. We subsequently retrospectively evaluated 40 consecutive patients who underwent a follow-up radiograph using the modified-technique after an initial standard-technique radiograph. We evaluated comparisons of proportions for subjective assessment with chi-squared tests, and agreements of reader's scores with intraclass correlation coefficients and Bland–Altman plots. We determined incident air kerma, exposure index, deviation index/standard deviation, dose-area product (DAP), and effective dose for each radiograph. We set statistical significance at P<0.05. Results: Forty patients (65% female), aged 4–17 years. Median effective dose was reduced from 39 to 10 µSv (P<0.001), incident air kerma from 139 to 29 µSv (P<0.001), and DAP from 266 to 55 mGy*cm2 (P<0.001). All modified-technique parameters were rated with a mean score of acceptable or above. All modified-technique measurements obtained inter- and intra-observer correlation coefficient agreements of 0.86 ("Good") or greater. Conclusion: Substantial dose reduction on follow-up scoliosis imaging with existing radiography units is achievable through task-based definition of adequate image quality and tailoring of radiation to each patient's height and weight, while still allowing for reliable assessment and reproducible measurements. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03010449
Volume :
54
Issue :
1
Database :
Academic Search Index
Journal :
Pediatric Radiology
Publication Type :
Academic Journal
Accession number :
174688366
Full Text :
https://doi.org/10.1007/s00247-023-05812-5