Clinical Use of a Commercial Artificial Intelligence-Based Software for Autocontouring in Radiation Therapy: Geometric Performance and Dosimetric Impact.

Authors :
Hoque, S M Hasibul
Pirrone, Giovanni
Matrone, Fabio
Donofrio, Alessandra
Fanetti, Giuseppe
Caroli, Angela
Rista, Rahnuma Shahrin
Bortolus, Roberto
Avanzo, Michele
Drigo, Annalisa
Chiovati, Paola
Source :
Cancers. Dec2023, Vol. 15 Issue 24, p5735. 25p.
Publication Year :
2023

Abstract

Simple Summary: Auto contouring driven by artificial intelligence can improve the workflow of radiotherapy by accelerating the contouring process. However, quality assurance of artificial intelligence-based tools is necessary for ensuring safety and efficacy in a clinical practice. In this study investigated the geometric accuracy of structural contours created by a commercial software for autocontouring based on artificial intelligence using well established metrics. In particular, the impact on the radiotherapy treatment plan quality from the adoption of artificial intelligence generated contours was investigated. Our results show that the combination of automatically generated contours and careful review by a clinical radiation oncologist results in time saving without affecting the quality of treatment plan. In conclusion, after quality checks that involve both geometric accuracy as well as dosimetric impact, contouring based on AI can be safely adopted in clinical practice. Purpose: When autocontouring based on artificial intelligence (AI) is used in the radiotherapy (RT) workflow, the contours are reviewed and eventually adjusted by a radiation oncologist before an RT treatment plan is generated, with the purpose of improving dosimetry and reducing both interobserver variability and time for contouring. The purpose of this study was to evaluate the results of application of a commercial AI-based autocontouring for RT, assessing both geometric accuracies and the influence on optimized dose from automatically generated contours after review by human operator. Materials and Methods: A commercial autocontouring system was applied to a retrospective database of 40 patients, of which 20 were treated with radiotherapy for prostate cancer (PCa) and 20 for head and neck cancer (HNC). Contours resulting from AI were compared against AI contours reviewed by human operator and human-only contours using Dice similarity coefficient (DSC), Hausdorff distance (HD), and relative volume difference (RVD). Dosimetric indices such as Dmean, D0.03cc, and normalized plan quality metrics were used to compare dose distributions from RT plans generated from structure sets contoured by humans assisted by AI against plans from manual contours. The reduction in contouring time obtained by using automated tools was also assessed. A Wilcoxon rank sum test was computed to assess the significance of differences. Interobserver variability of the comparison of manual vs. AI-assisted contours was also assessed among two radiation oncologists for PCa. Results: For PCa, AI-assisted segmentation showed good agreement with expert radiation oncologist structures with average DSC among patients ≥ 0.7 for all structures, and minimal radiation oncology adjustment of structures (DSC of adjusted versus AI structures ≥ 0.91). For HNC, results of comparison between manual and AI contouring varied considerably e.g., 0.77 for oral cavity and 0.11–0.13 for brachial plexus, but again, adjustment was generally minimal (DSC of adjusted against AI contours 0.97 for oral cavity, 0.92–0.93 for brachial plexus). The difference in dose for the target and organs at risk were not statistically significant between human and AI-assisted, with the only exceptions of D0.03cc to the anal canal and Dmean to the brachial plexus. The observed average differences in plan quality for PCa and HNC cases were 8% and 6.7%, respectively. The dose parameter changes due to interobserver variability in PCa were small, with the exception of the anal canal, where large dose variations were observed. The reduction in time required for contouring was 72% for PCa and 84% for HNC. Conclusions: When an autocontouring system is used in combination with human review, the time of the RT workflow is significantly reduced without affecting dose distribution and plan quality. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20726694
Volume :
15
Issue :
24
Database :
Academic Search Index
Journal :
Cancers
Publication Type :
Academic Journal
Accession number :
174403385
Full Text :
https://doi.org/10.3390/cancers15245735