Back to Search Start Over

Analytical improvements and assessment of long‐term performance of the oxidation–denitrifier method.

Authors :
Moretti, Simone
Duprey, Nicolas N.
Foreman, Alan D.
Arns, Anthea
Brömme, Sven
Jung, Jonathan
Ai, Xuyuan E.
Auderset, Alexandra
Bieler, Aaron L.
Eck, Camino
Farmer, Jesse
Hinnenberg, Barbara
Lacerra, Matthew
Leichliter, Jennifer
Lüdecke, Tina
Oleynik, Sergey
Rubach, Florian
Schmitt, Mareike
Vink, Marissa
Wald, Tanja
Source :
Rapid Communications in Mass Spectrometry: RCM. Jan2024, Vol. 38 Issue 1, p1-19. 19p.
Publication Year :
2024

Abstract

The analysis of the nitrogen (N) isotopic composition of organic matter bound to fossil biomineral structures (BB‐δ15N) using the oxidation–denitrifier (O–D) method provides a novel tool to study past changes in N cycling processes. Methods: We report a set of methodological improvements to the O–D method, including (a) a method for sealing the reaction vials in which the oxidation of organic N to NO3− takes place, (b) a recipe for bypassing the pH adjustment step before the bacterial conversion of NO3− to N2O, and (c) a method for storing recrystallized dipotassium peroxodisulfate (K2S2O8) under Ar atmosphere. Results: The new sealing method eliminates the occasional contamination and vial breakage that occurred previously while increasing sample throughput. The protocol for bypassing pH adjustment does not affect BB‐δ15N, and it significantly reduces the processing time. Storage of K2S2O8 reagent under Ar atmosphere produces stable oxidation blanks over more than 3.5 years. We report analytical blanks, accuracy, and precision for this methodology from eight users over the course of ~3.5 years of analyses at the Max Planck Institute for Chemistry. Our method produces analytical blanks characterized by low N content (0.30 ± 0.13 nmol N, 1σ, n = 195) and stable δ15N (−2.20 ± 3.13‰, n = 195). The analysis of reference amino acid standards USGS 40 and USGS 65 indicates an overall accuracy of −0.23 ± 0.35‰ (1σ, n = 891). The analysis of in‐house fossil standards gives similar analytical precision (1σ) across a range of BB‐δ15N values and biominerals: zooxanthellate coral standard PO‐1 (6.08 ± 0.21‰, n = 267), azooxanthellate coral standard LO‐1 (10.20 ± 0.28‰, n = 258), foraminifera standard MF‐1 (5.92 ± 0.28‰, n = 243), and tooth enamel AG‐Lox (4.06 ± 0.49‰, n = 78). Conclusions: The methodological improvements significantly increase sample throughput without compromising analytical precision or accuracy down to 1 nmol of N. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09514198
Volume :
38
Issue :
1
Database :
Academic Search Index
Journal :
Rapid Communications in Mass Spectrometry: RCM
Publication Type :
Academic Journal
Accession number :
174157780
Full Text :
https://doi.org/10.1002/rcm.9650