Femtomolar detection of the heart failure biomarker NT-proBNP in artificial saliva using an immersible liquid-gated aptasensor with reduced graphene oxide.
- Source :
-
Microchemical Journal . Jan2024, Vol. 196, pN.PAG-N.PAG. 1p. - Publication Year :
- 2024
-
Abstract
- [Display omitted] • Aptamer-conjugated rGO-FET biosensor on commercially available IDE chip was developed. • Proper choice of solution ionic strength improves the performance of aptasensor to NT-proBNP. • Realistic model of biosensing considering the size of aptamer and analyte molecule is suggested. • Correlation analysis of independent aptasensor parameters was proposed to increase its reliability. • Aptasensor enables on-site detection of NT-proBNP in artificial saliva with LOD 41 fg/mL. Measuring NT-proBNP biomarker is recommended for preliminary diagnostics of the heart failure. Recent studies suggest a possibility of early screening of biomarkers in saliva for non-invasive identification of cardiac diseases at the point-of-care. However, NT-proBNP concentrations in saliva can be thousand time lower than in blood plasma, going down to pg/mL level. To reach this level, we developed a label-free aptasensor based on a liquid-gated field effect transistor using a film of reduced graphene oxide monolayer (rGO-FET) with immobilized NT-proBNP specific aptamer. We found that, depending on ionic strength of tested solutions, there were different levels of correlation in responses of electrical parameters of the rGO-FET aptasensor, namely, the Dirac point shift and transconductance change. The correlation in response to NT-proBNP was high for 1.6 mM phosphate-buffered saline (PBS) and zero for 16 mM PBS in a wide range of analyte concentrations, varied from 1 fg/mL to 10 ng/mL. The effects of transconductance and Dirac point shift in PBS solutions of different concentrations are discussed. The biosensor exhibited a high sensitivity for both transconductance (2 µS/decade) and Dirac point shift (2.3 mV/decade) in diluted PBS with the linear range from 10 fg/mL to 1 pg/mL. The aptasensor performance has been also demonstrated in undiluted artificial saliva with the achieved limit of detection down to 41 fg/mL (∼4.6 fM). [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0026265X
- Volume :
- 196
- Database :
- Academic Search Index
- Journal :
- Microchemical Journal
- Publication Type :
- Academic Journal
- Accession number :
- 174012772
- Full Text :
- https://doi.org/10.1016/j.microc.2023.109611