Back to Search
Start Over
Parameter Estimation of Squirrel-cage Machine using Laboratory Tests.
- Source :
-
Computational Intelligence in Electrical Engineering . Fall2023, Vol. 14 Issue 3, p149-153. 5p. - Publication Year :
- 2023
-
Abstract
- Recently, studies of squirrel-cage induction machines validate the idea that these machines follow the double-cage induction model; however, the manufacturers categorize these machines as single-cage machines. There are many references that use the squirrel-model for squirrel-cage machines, then machine parameters increase from 5 to 7. In the laboratory, parameter determination is performed to estimate 5 parameters; however, 7 parameters have to be determined. Also, the DC test is not an exact test and is used for approximate estimation. Therefore, locked rotor test equations are changed and an overload test is added. After measurements in the laboratory according to the equations of this paper, a MATLAB program is prepared and 7 parameters are determined in a loop until reaching the desired error. This paper demonstrates that laboratory squirrel-cage machines have to be corrected using the 7-parameter model. Furthermore, this paper shows the necessity of new laboratory test equations for squirrel-cage machines. Then a numerical method is used to determine the machine parameters. [ABSTRACT FROM AUTHOR]
Details
- Language :
- Modern Greek
- ISSN :
- 28210689
- Volume :
- 14
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- Computational Intelligence in Electrical Engineering
- Publication Type :
- Academic Journal
- Accession number :
- 173683838
- Full Text :
- https://doi.org/10.22108/ISEE.2022.132395.1541