Back to Search Start Over

Organophosphate ester (OPE) exposure among waste recycling and administrative workers in Denmark using silicone wristbands.

Authors :
Hammel, Stephanie C.
Hansen, Karoline K.
Madsen, Anne Mette
Kolstad, Henrik A.
Schlünssen, Vivi
Frederiksen, Marie
Source :
Chemosphere. Dec2023, Vol. 345, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

In a recent estimate, 96 million tons of hazardous waste were produced in the European Union, most of which were handled among the member states. Organophosphate esters (OPEs) are applied as flame retardants and plasticizers and are present in many products, e.g., electronics, which end up in the hazardous waste stream upon disposal. Given the growing body of information suggesting potential adverse health effects of OPEs, waste recycling workers who handle hazardous waste could potentially be at risk of elevated exposure to these chemicals. Using silicone wristbands, we evaluated OPE exposure among waste recycling workers who handled hazardous waste and compared their exposure to that of administrative workers from the same waste companies. Wristbands were extracted and analyzed for six OPEs, which were all detected in >75% of wristbands. Overall, the sum of tris(2-chloroisopropyl) phosphate (∑TCIPP) isomers was the most abundant OPE across all wristbands collected within the study. In general, the sum of tri(methyl phenyl) phosphate isomers (∑TMPP) was elevated for all waste workers (10β = 7.9), whereas tri- n -butyl phosphate (TnBP), tris(1,3-dichloroisopropyl) phosphate (TDCIPP), and ∑TMPP were 3–12 times higher among those specifically handling electronic and hazardous waste compared to the administrative workers (p < 0.05). Repeated wristband measurements from the same worker had fair to good consistency in OPE concentrations (intraclass correlation coefficients = 0.54–0.77), except for the two most volatile chlorinated OPEs. Taken together, our results suggest that waste recycling workers who handle electronic and hazardous waste have significantly elevated exposure to OPEs, and efforts to reduce these exposures should be considered. [Display omitted] • Silicone wristbands were used to measure OPE exposure among waste recycling workers. • ∑TCIPP was detected in every wristband and was the most abundant across all workers. • Wristband OPEs were higher for waste recycling compared to administrative workers. • TnBP, ∑TMPP and TDCIPP were higher for handlers of electronic and hazardous waste. • Repeat wristbands had fair to good consistency for most OPEs across samplings. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00456535
Volume :
345
Database :
Academic Search Index
Journal :
Chemosphere
Publication Type :
Academic Journal
Accession number :
173525828
Full Text :
https://doi.org/10.1016/j.chemosphere.2023.140449