Back to Search Start Over

Magnetically-targetable outer-membrane vesicles for sonodynamic eradication of antibiotic-tolerant bacteria in bacterial meningitis.

Authors :
Shi, Rui
Lv, Rui
Dong, Ziliang
Cao, Qinghua
Wu, Renfei
Liu, Sidi
Ren, Yijin
Liu, Zhuang
van der Mei, Henny C.
Liu, Jian
Busscher, Henk J.
Source :
Biomaterials. Nov2023, Vol. 302, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

Treatment of acute bacterial meningitis is difficult due to the impermeability of the blood-brain barrier, greatly limiting the antibiotic concentrations that can be achieved in the brain. Escherichia coli grown in presence of iron-oxide magnetic nanoparticles secrete large amounts of magnetic outer-membrane vesicles (OMVs) in order to remove excess Fe from their cytoplasm. OMVs are fully biomimetic nanocarriers, but can be inflammatory. Here, non-inflammatory magnetic OMVs were prepared from an E. coli strain in which the synthesis of inflammatory lipid A acyltransferase was inhibited using CRISPR/Cas9 mediated gene knockout. OMVs were loaded with ceftriaxone (CRO) and meso-tetra-(4-carboxyphenyl)porphine (TCPP) and magnetically driven across the blood-brain barrier for sonodynamic treatment of bacterial meningitis. ROS-generation upon ultrasound application of CRO- and TCPP-loaded OMVs yielded similar ROS-generation as by TCPP in solution. In vitro , ROS-generation by CRO- and TCPP-loaded OMVs upon ultrasound application operated synergistically with CRO to kill a hard-to-kill, CRO-tolerant E. coli strain. In a mouse model of CRO-tolerant E. coli meningitis, CRO- and TCPP-loaded OMVs improved survival rates and clinical behavioral scores of infected mice after magnetic targeting and ultrasound application. Recurrence did not occur for at least two weeks after arresting treatment. [Display omitted] • Magnetically-harvested OMVs can be magnetically driven across the blood-brain barrier • Magnetic OMVs can be loaded with an antibiotic and a sonosensitizer • Antibiotics work synergistically in bacterial killing with sonodynamically generated ROS • Magnetic OMVs loaded with CRO and TCPP effectively cures murine, bacterial meningitis • Treatment with CRO-TCPP loaded OMVs delays recurrence of murine, bacterial meningitis [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01429612
Volume :
302
Database :
Academic Search Index
Journal :
Biomaterials
Publication Type :
Academic Journal
Accession number :
173342708
Full Text :
https://doi.org/10.1016/j.biomaterials.2023.122320