Back to Search
Start Over
Tests, numerical simulations and design of G550 high strength cold-formed steel lipped channel section columns failing by interactive buckling.
- Source :
-
Thin-Walled Structures . Nov2023, Vol. 192, pN.PAG-N.PAG. 1p. - Publication Year :
- 2023
-
Abstract
- • The structural performance of G550 high strength CFS lipped channel section columns was studied. • 10 axial compression tests on G550 high strength CFS lipped channel section columns were conducted. • FE models were developed and validated against test results and then used to perform parametric studies. • The current design methods were evaluated for their applicability to G550 high strength CFS lipped channel section columns. This paper presents the experimental and numerical investigations into the structural performance and strengths of G550 high strength cold-formed steel (CFS) lipped channel section columns failing by interactive buckling. A testing program was first conducted, comprising material testing, measurements of initial local, distortional and global geometric imperfections and ten pin-ended column tests. The interaction between different buckling modes was observed and discussed for all the examined specimens upon testing. A numerical modeling program was subsequently performed, where numerical models were created and verified with reference to the test results and afterwards utilized to conduct parametric analysis to produce more numerical data over an extensive spectrum of cross-section geometries and effective member lengths. The effective width method (EWM) codified in the European code and direct strength method (DSM) specified in American and Australian standards were evaluated, based on the combined set of numerical and test data, for their suitability to G550 high strength CFS lipped channel section columns susceptible to interactive buckling. The evaluation results indicated that (i) the EWM yielded scattered and conservative ultimate strengths for columns with small and intermediate slenderness ratios, but relatively accurate results for those of large slenderness ratios and (ii) the DSM led to more consistent and accurate strength predictions for G550 high strength CFS lipped channel section columns failing by interactive buckling, though a number of strength predictions were on the unsafe side. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02638231
- Volume :
- 192
- Database :
- Academic Search Index
- Journal :
- Thin-Walled Structures
- Publication Type :
- Academic Journal
- Accession number :
- 173156182
- Full Text :
- https://doi.org/10.1016/j.tws.2023.111172