The Estimation of Resistivity of Poka Alluvial Plain Material by Geoelectric Method with Wenner-Schlumberger Configuration.

Authors :
Latupapua, Andrias Izaac
Tahapary, Fahrul Dadan
Soplanit, Rudy
Source :
International Journal of Multidisciplinary: Applied Business & Education Research. Sep2023, Vol. 4 Issue 9, p3116-3122. 7p.
Publication Year :
2023

Abstract

This study was conducted to determine the lateral and vertical distribution of material resistivity values on Poka alluvial plain using electrodes with Wenner-Schlumberger configuration. Mapping is carried out on 2 lines each 120 m long with the smallest space of 10 m. The results showed that the resistivity of the material ranged from 48.8 Om to 2.247 Om spread laterally with a depth of up to 26.2 m. Loose Sand material occupies the upper layer, followed by the Alluvium and Sand layers in the middle, and Sand and Water which are unconfined aquifers in the lower layer. [ABSTRACT FROM AUTHOR]