Back to Search Start Over

Loss of Blink Regularity and Its Impact on Ocular Surface Exposure.

Authors :
Cardona, Genis
Argilés, Marc
Pérez-Cabré, Elisabet
Source :
Diagnostics (2075-4418). Jul2023, Vol. 13 Issue 14, p2362. 9p.
Publication Year :
2023

Abstract

(1) Background: Changes in blink parameters have been found to influence ocular surface exposure, eliciting symptoms of dry eye and ocular signs. The aim of the study was to highlight the relevance of including blink regularity as a new parameter to fully characterize blinking; (2) Methods: A novel characterization of blink parameters is described, including spontaneous eyeblink rate (SEBR), percentage of incomplete blinks, and blink regularity. A pilot study was designed in which tear film break-up time (TFBUT), blink parameters, and the time percentage of ocular surface exposure were determined in eight subjects (52.0 ± 16.6 years, 4 females) in three experimental conditions (baseline, reading a hard-copy text, and reading from an electronic display). Blink parameters were monitored through asynchronous image analysis of one minute video segments; (3) Results: All blink parameters were influenced by experimental conditions. A trend was observed in which both reading tasks resulted in an increase in ocular surface exposure, mainly related to a combination of reduced SEBR, increased percentage of incomplete blinks, and loss of blink regularity; (4) Conclusions: A complete characterization of blink parameters is relevant to better understand ocular dryness related to surface exposure and to advice patients towards a reeducation of their blinking habits. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20754418
Volume :
13
Issue :
14
Database :
Academic Search Index
Journal :
Diagnostics (2075-4418)
Publication Type :
Academic Journal
Accession number :
168599349
Full Text :
https://doi.org/10.3390/diagnostics13142362