Back to Search Start Over

Surface oxidation using chlorine dioxide for cuprite and its oxidation leaching mechanism in sulfuric acid solution.

Authors :
Yang, Jing
Shi, Yunfeng
Chen, Luzheng
Wu, Dandan
Source :
Applied Surface Science. Nov2023, Vol. 637, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

[Display omitted] • The pretreatment of chlorine dioxide was developed for cuprite in acid leaching. • The Cu+ on the cuprite surface was effectively oxidized to Cu2+ by chlorine dioxide. • The disproportionation of cuprite in acid leaching was mostly inhibited by pretreatment. • The copper extraction rate of cuprite was greatly improved by oxidation leaching. Cuprite (Cu 2 O) is difficult to directly leach in acidic solutions. In the absence of oxygen, the acidic leaching process of cuprite occurs via a disproportionation reaction and can achieve a maximum cuprite leaching rate of only 50%. Furthermore, to improve the copper leaching rate, Cu(Ι) in cuprite must be oxidized via electrochemical reactions. In this study, chlorine dioxide (ClO 2), a novel environmentally-friendly oxidant, was used to oxidize cuprite to enhance the leaching effect in sulfuric acid (H 2 SO 4) solution. Leaching experiments, electrochemical measurements, atomic force microscopy (AFM), scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS), X-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were used to analyze the oxidation leaching mechanism of cuprite under different reaction conditions. Under the condition of a leaching temperature of 50 °C, sulfuric acid concentration of 0.14 mol/L, average particle size of 60 μm, stirring speed of 800 rpm, and leaching time of 30 min, the leaching rate of cuprite reached 90.18% after adding 0.07 mol/L of ClO 2. Electrochemical measurements demonstrated that a higher ClO 2 concentration increased the corrosion rate of cuprite and oxidation efficiency. Moreover, the surface characterization results showed that with the addition of ClO 2 , monovalent copper on the cuprite surface was oxidized to divalent copper, which promoted the acidic leaching process of cuprite. In addition, once the cuprite surface was oxidized during oxidation leaching, sulfuric acid leached this layer until the end of the leaching process. The DFT calculation results further proved that with the participation of ClO 2 , the leaching reaction of cuprite in an acidic solution was more likely to occur. This oxidation leaching method might provide a reference for the effective leaching of cuprite. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01694332
Volume :
637
Database :
Academic Search Index
Journal :
Applied Surface Science
Publication Type :
Academic Journal
Accession number :
164962520
Full Text :
https://doi.org/10.1016/j.apsusc.2023.157892