Back to Search Start Over

Accelerometer sampling requirements for animal behaviour classification and estimation of energy expenditure.

Authors :
Yu, Hui
Muijres, Florian T.
te Lindert, Jan Severin
Hedenström, Anders
Henningsson, Per
Source :
Animal Biotelemetry. 7/15/2023, Vol. 11 Issue 1, p1-14. 14p.
Publication Year :
2023

Abstract

Background: Biologgers have contributed greatly to studies of animal movement, behaviours and physiology. Accelerometers, among the various on-board sensors of biologgers, have mainly been used for animal behaviour classification and energy expenditure estimation. However, a general principle for the combined sampling duration and frequency for different taxa is lacking. In this study, we evaluated whether Nyquist–Shannon sampling theorem applies to accelerometer-based classification of animal behaviour and energy expenditure approximation. To evaluate the influence of accelerometer sampling frequency on behaviour classification, we annotated accelerometer data from seven European pied flycatchers (Ficedula hypoleuca) freely moving in aviaries. We also used simulated data to systematically evaluate the combined effect of sampling duration and sampling frequency on the performance of estimating signal frequency and amplitude. Results: We found that a sampling frequency higher than Nyquist frequency at 100 Hz was needed to classify fast, short-burst behavioural movements of pied flycatcher, such as swallowing food with a mean frequency of 28 Hz. In contrast, high frequency movements with longer durations such as flight could be characterized adequately using much lower sampling frequency of 12.5 Hz. To identify rapid transient prey catching manoeuvres within these flight bouts, again a high frequency sampling at 100 Hz was needed. For both the experimental data of the flycatchers and the simulated data, the combination of sampling frequency and sampling duration affected the accuracy of signal frequency and amplitude estimation. For long sampling durations, the sampling frequency equal to the Nyquist frequency was adequate for accurate signal frequency and amplitude estimation. Accuracy declined with decreasing sampling duration, especially for signal amplitude estimation with up to 40% standard deviation of normalized amplitude difference. To accurately estimate signal amplitude at low sampling duration, a sampling frequency of four times the signal frequency was necessary (two times the Nyquist frequency). Conclusions: The appropriate sampling frequency of accelerometers depends on the objective of the specific study and the characteristics of the behaviour. For studies with no constraints on device battery and storage, a sampling frequency of at least two times the Nyquist frequency will achieve relative optimal representative of signal information (i.e., frequency and amplitude). For classification and energy expenditure estimation of short-burst behaviours, 1.4 times the Nyquist frequency of behaviour is required. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20503385
Volume :
11
Issue :
1
Database :
Academic Search Index
Journal :
Animal Biotelemetry
Publication Type :
Academic Journal
Accession number :
164947410
Full Text :
https://doi.org/10.1186/s40317-023-00339-w