Back to Search Start Over

Reliability of surface electromyographic (sEMG) measures of equine axial and appendicular muscles during overground trot.

Authors :
St. George, L.
Spoormakers, T. J. P.
Roy, S. H.
Hobbs, S. J.
Clayton, H. M.
Richards, J.
Serra Bragança, F. M.
Source :
PLoS ONE. 7/14/2023, Vol. 18 Issue 7, p1-22. 22p.
Publication Year :
2023

Abstract

The reliability of surface electromyography (sEMG) has not been adequately demonstrated in the equine literature and is an essential consideration as a methodology for application in clinical gait analysis. This observational study investigated within-session, intra-subject (stride-to-stride) and inter-subject reliability, and between-session reliability of normalised sEMG activity profiles, from triceps brachii (triceps), latissimus dorsi (latissimus), longissimus dorsi (longissimus), biceps femoris (biceps), superficial gluteal (gluteal) and semitendinosus muscles in n = 8 clinically non-lame horses during in-hand trot. sEMG sensors were bilaterally located on muscles to collect data during two test sessions (session 1 and 2) with a minimum 24-hour interval. Raw sEMG signals from ten trot strides per horse and session were DC-offset removed, high-pass filtered (40 Hz), full-wave rectified, and low-pass filtered (25 Hz). Signals were normalised to peak amplitude and percent stride before calculating intra- and inter-subject ensemble average sEMG profiles across strides for each muscle and session. sEMG profiles were assessed using waveform similarity statistics: the coefficient of variation (CV) to assess intra- and inter-subject reliability and the adjusted coefficient of multiple correlation (CMC) to evaluate between-session reliability. Across muscles, CV data revealed that intra-horse sEMG profiles within- and between-sessions were comparatively more reliable than inter-horse profiles. Bilateral gluteal, semitendinosus, triceps and longissimus (at T14 and L1) and right biceps showed excellent between-session reliability with group-averaged CMCs > 0.90 (range 0.90–0.97). Bilateral latissimus and left biceps showed good between-session reliability with group-averaged CMCs > 0.75 (range 0.78–0.88). sEMG profiles can reliably describe fundamental muscle activity patterns for selected equine muscles within a test session for individual horses (intra-subject). However, these profiles are more variable across horses (inter-subject) and between sessions (between-session reliability), suggesting that it is reasonable to use sEMG to objectively monitor the intra-individual activity of these muscles across multiple gait evaluation sessions at in-hand trot. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
18
Issue :
7
Database :
Academic Search Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
164935565
Full Text :
https://doi.org/10.1371/journal.pone.0288664