Back to Search Start Over

Uniaxial dynamic behavior of foam glass aggregate under oedometric (fully side restrained) condition at different compaction ratios.

Authors :
Mustafa, Waleed Sulaiman
Szendefy, János
Source :
Construction & Building Materials. Sep2023, Vol. 396, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

• Cyclic loads applied on foam glass aggregates (FGA) at different compaction ratios. • FGA response under deviatoric stresses 25 kPa, 100 kPa, and 200 kPa was investigated. • Resilient modulus (M r) and accumulated plastic strain (ɛ acc) were measured. • Increasing the compaction ratio led to a significant decrease in ɛ acc values. • Revealed that FGA at 40% can be used in infrastructure base layer material. Foam glass aggregate (FGA) is considered as a lightweight and thermal insulation material. It has a wide granular size distribution nature that can influence the material's dynamic response when subjected to moving loads. Therefore, it is crucial to investigate the impact of different compaction ratios on the material's dynamic behavior. This study focused on examining the effects of varying compaction ratios (10%, 20%, 30%, and 40%) on dynamic parameters such as resilient stiffness (M r) and accumulated plastic strains (ɛ acc) of FGA. Uniaxial deviatoric stresses were applied to the material samples in a series to assess their influence on the material's behavior over multiple cycles. The results revealed the significant influence of increasing the compaction ratio to 40% on the material's behavior. At this compaction ratio, the ɛ acc decreased to approximately 71%, 69%, and 86% for deviatoric stresses of 25 kPa, 100 kPa, and 200 kPa, respectively, after subjecting the material to 40,000 cycles. The increase in recoverable strains resulting from the material's fragile property under higher compaction energy led to a decrease in the M r values of FGA samples as the compaction ratios increased. The lower boundary of M r values for FGA ranged from 102 MPa to 189 MPa, while the upper boundary ranged from 150 MPa to 219 MPa under the selected deviatoric stresses. Although the interpretation of the shakedown criterion limitations yielded varying ranges for the colocation of FGA samples, it was found that FGA samples compacted at 40% exhibited robust characteristics suitable for constructing road embankments. This can be beneficial for infrastructure applications due to their excellent lightweight and thermal insulation properties. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09500618
Volume :
396
Database :
Academic Search Index
Journal :
Construction & Building Materials
Publication Type :
Academic Journal
Accession number :
164858618
Full Text :
https://doi.org/10.1016/j.conbuildmat.2023.132327