Research on the Effects of Detector Shape on Spectral Calibration of Infrared Hyperspectral Interferometer Based on Simulation Data.

Authors :
Ni, Zhuoya
Lu, Qifeng
Huo, Hongyuan
Wu, Chunqiang
Source :
International Journal of Remote Sensing. Jun2023, p1-21. 21p. 13 Illustrations, 1 Chart.
Publication Year :
2023

Abstract

Infrared hyperspectral instrument is a complex optical instrument. The requirement for the application of the infrared hyperspectral interferometer is fine calibration accuracy. The accuracy of the spectral frequency of the infrared hyperspectral interferometer is a key influencing factor of the radiometric calibration accuracy. In order to meet the quantitative application, the spectral calibration accuracy is generally within 10ppm. For infrared hyperspectral instruments in geostationary orbit, the focal plane has the characteristics of large array and small detector size. When the detector size of an infrared hyperspectral interferometer is in the geostationary orbit whether the detector as a point detector will affect the spectral calibration accuracy. In this paper, we simulate and analyze the influence of the shape of the detector (square and point detector) on the spectral calibration accuracy. This paper first builds an infrared hyperspectral observation and calibration simulation model. The brightness temperature deviation between the calibration spectrum and the input spectrum is close to 0 K, which shows the rationality of building the simulation model. Then, in the process of spectral calibration, two methods, square detectors and point detectors, are adopted, respectively. The spectral calibration of the square detector needs to calculate the line shape function of the instrument according to the detector position. Regarding point detector spectral calibration, this paper proposes a spectral calibration parameter optimization algorithm based on the optimization algorithm, which does not depend on the physical parameters of the instrument, but only uses the observed simulated spectrum and the reference spectrum. The results show that the spectral calibration accuracy of the point detector based on the optimization method can be close to 0ppm, which is consistent with the spectral calibration accuracy of the square detector. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01431161
Database :
Academic Search Index
Journal :
International Journal of Remote Sensing
Publication Type :
Academic Journal
Accession number :
164553520
Full Text :
https://doi.org/10.1080/01431161.2023.2224103