Back to Search Start Over

First measurements of a scintillator-based fast-ion loss detector in reversed Ip/Bt at the ASDEX Upgrade tokamak.

Authors :
Hidalgo-Salaverri, J.
Rueda-Rueda, J.
Galdon-Quiroga, J.
Cano-Megias, P.
Viezzer, E.
Garcia-Dominguez, J.
Silvagni, D.
Videla-Trevin, M.
Oyola, P.
Ayllon-Guerola, J.
Garcia-Munoz, M.
Happel, T.
Source :
Fusion Engineering & Design. Aug2023, Vol. 193, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

Fast-α losses in future fusion power plants are expected to follow the co- and counter-current directions due to the isotropy of the fusion reaction. At the ASDEX Upgrade tokamak, the co-current direction (achieved with positive plasma current and negative toroidal magnetic field) has been extensively studied thanks to an array of five fast-ion loss detectors (FILD). A new fast-ion loss detector compatible with reversed I p /B t (negative plasma current and positive magnetic toroidal field, defining positive as counter-clockwise when the machine is viewed from the top), namely RFILD, has been designed and commissioned to study the behaviour of counter-current fast-ion losses and to expand our knowledge on QH-mode, I-mode, and the L-H transition. The detector is a modified version of the midplane manipulator fast-ion loss detector that features a new probe head orientation and collimator geometry, optimised using the FILDSIM code. A fast CMOS camera is used as a high spatial resolution acquisition system, while an array of photomultipliers (up to 1 MHz) serves as a fast channel. First measurements have been taken in I-mode, QH-mode, L-mode and H-mode with core densities ranging between 4·1019 and 9·1019 m−3, I P between -0.8 and -0.6 MA and B t of 2.5 T approximately. NBI fast-ion losses were observed for the first time in reversed I p /B t , producing high pitch (60 – 80°) losses. ICRH losses in H-minority heating configuration have also been observed in I-mode experiments. These losses correspond to the outer leg of banana particle trajectories. An upgraded double collimator detector design is also presented, that will increase the measurable particle range in future experimental campaigns (co- and counter-current particles simultaneously). Thus, we expand our understanding on the mechanisms behind fast-ion losses at the ASDEX Upgrade tokamak in the reversed I p /B t configuration. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09203796
Volume :
193
Database :
Academic Search Index
Journal :
Fusion Engineering & Design
Publication Type :
Academic Journal
Accession number :
164345248
Full Text :
https://doi.org/10.1016/j.fusengdes.2023.113661