Back to Search Start Over

Electrochemical determination of zearalenone in agricultural food samples using a flower like nanocomposite-modified electrode.

Authors :
Zaman, Gaffar Sarwar
Waleed, Ibrahem
Obeid, Ruaa Ali
Khudair, Shaymaa Abdulhameed
Al-Kahdum, Saafa Abaas Abd
Al-Majdi, Kadhum
Abed, Ahmed S.
Alsalamy, Ali
Qasim, Maytham T.
Radie Alawadi, Ahmed Hussien
Source :
Materials Chemistry & Physics. Sep2023, Vol. 305, pN.PAG-N.PAG. 1p.
Publication Year :
2023

Abstract

We detected Zearalenone in real dairy, juices and other liquid food specimens using a screen-printed electrode (SPE) modified with a new three dimensional carnation flower-like Tb3+/Co 3 O 4 nanocomposite (3D CF-L Tb3+/Co 3 O 4 NC sensor). The physicochemical properties of the 3D CF-L Tb3+/Co 3 O 4 NC were characterized by X-ray diffraction (XRD), field emission scanning electron microscope (FE-SEM) and energy dispersive X-ray spectroscope (EDX) methods. The appreciable properties of the as-prepared sensor were high electrical conductivity, large surface area, abundant binding sites and excellent stability. The electrochemical analysis of the modified electrode was characterized by differential pulse voltammetry, electrochemical impedance spectroscopy, cyclic voltammetry and chronoamperometry. The peak current of Zearalenone was variable based on changes in pH values due to its proton receptor groups. The best signal of Zearalenone in the phosphate buffer solution on the basis of the maximum signal of received stream was observed at the pH value of 7.0. The sensor showed a wide linear dynamic range (0.001–500.0 μM) and a narrow limit of detection (0.34 nM) for the Zearalenone concentration. Our electrochemical sensor was also successful in determination of Zearalenone in the real samples. Electrochemical sensor based on three dimensional carnation flower-like Tb3+/Co 3 O 4 nanocomposite modified screen printed electrode for detecting Zearalenone was fabricated. [Display omitted] • The synthesis of CF-L Tb3+/Co 3 O 4 NC was based on the hydrothermal method. • Novel modified electrode for Zearalenone determination was developed. • LODs of the detection of Zearalenone was found to be very low. • It used for determination of Zearalenone in real samples. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02540584
Volume :
305
Database :
Academic Search Index
Journal :
Materials Chemistry & Physics
Publication Type :
Academic Journal
Accession number :
164248581
Full Text :
https://doi.org/10.1016/j.matchemphys.2023.127986