Back to Search Start Over

Visual function assessment of Chinese cataract patients after individual aspheric intraocular lens implantation according to preoperative cornea spherical aberration.

Authors :
Duan, Lian
Dang, Guangfu
Ge, Jinling
Gao, Yang
Wang, Lihua
Source :
Technology & Health Care. 2023, Vol. 31 Issue 3, p831-839. 9p.
Publication Year :
2023

Abstract

<bold>Background: </bold>Aspheric intraocular lens (IOLs) implantation has been widely applied in cataract surgery. However, there is no consensus on the optimal guidance for the operations in IOLs implantation.<bold>Objective: </bold>This study evaluated the visual function of Chinese cataract patients six months after cataract surgery with two different guiding ideologies.<bold>Methods: </bold>We evaluated 50 patients (61 eyes) with implantation of different aspheric IOLs (SN60WF IOLs, ZCB00 IOLs, PY-60AD IOLs, AO IOLs) 6 months after cataract surgery. Twenty-four patients (30 eyes) under individual implantation were ascribed to group 1 and 26 patients (31 eyes) with randomized implantation were ascribed to the control group (group 2). Postoperatively parameters included monocular best-corrected visual acuity (BCVA), contrast sensitivity (CS), total spherical aberration Z (4, 0) at 5 mm pupil size, and patient satisfaction. The quality of life after operation was assessed through the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25).<bold>Results: </bold>Six months after cataract operation, the contrast sensitivity with glare of group 1 at 2.5∘ was 0.697 ± 0.027, and 0.532 ± 0.049 in group 2. Besides, there was no significant difference at any other special frequency. The mean spherical aberration Z (4, 0) at 5 mm pupil size in group 1 was 0.015 ± 0.028 um, and in group 2 was 0.043 ± 0.109 um, with a significant difference (p< 0.01). The mean scores obtained from NEI VFQ-25 were not significantly different.<bold>Conclusion: </bold>It is effective to implant aspheric IOLs individually according to preoperative corneal spherical aberration. Patients obtained better contrast sensitivity with glare at 2.5∘, but there was no significant difference in BCVA, contrast sensitivity at other special frequency, and subjective visual function. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09287329
Volume :
31
Issue :
3
Database :
Academic Search Index
Journal :
Technology & Health Care
Publication Type :
Academic Journal
Accession number :
164047754
Full Text :
https://doi.org/10.3233/THC-220154