Back to Search
Start Over
Central venous pressure and dynamic indices to assess fluid appropriateness in critically ill patients: A pilot study.
- Source :
-
PLoS ONE . 5/18/2023, Vol. 17 Issue 5, p1-9. 9p. - Publication Year :
- 2023
-
Abstract
- Background: The correct identification of the appropriateness of fluid administration is important for the treatment of critically ill patients. Static and dynamic indices used to identify fluid responsiveness have been developed throughout the years, nonetheless fluid responsiveness does not indicate that fluid administration is appropriate, and indexes to evaluate appropriateness of fluid administration are lacking. The aim of this study was to evaluate if central venous pressure (CVP) anddynamic indices could correctly identify fluid appropriateness for critically ill patients. Methods: Data from 31 ICU patients, for a total of 53 observations, was included in the analysis. Patients were divided into two cohorts based on the appropriateness of fluid administration. Fluid appropriateness was defined in presence of a low cardiac index (< 2.5 l/min/m2) without any sign of fluid overload, as assessed by global end-diastolic volume index, extravascular lung water index or pulmonary artery occlusion pressure. Results: For 10 patients, fluid administration was deemed appropriate, while for 21 patients it was deemed inappropriate. Central venous pressure was not different between the two cohorts (mean CVP 11 (4) mmHg in the fluid inappropriate group, 12 (4) mmHg in the fluid appropriate group, p 0.58). The same is true for pulse pressure variation (median PPV 5 [2, 9] % in the fluid inappropriate group, 4 [3, 13] % in the fluid appropriate group, p 0.57), for inferior vena cava distensibility (mean inferior vena cava distensibility 24 (14) % in the fluid inappropriate group, 22 (16) % in the fluid appropriate group, p 0.75) and for changes in end tidal carbon dioxide during a passive leg raising test (median d.ETCO2 1.5 [0.0, 2.0]% in the fluid inappropriate group, 1.0 [0.0, 2.0] % in the fluid appropriate group, p 0.98). There was no association between static and dynamic indices and fluid appropriateness. Conclusions: Central venous pressure, pulse pressure variation, changes in end tidal carbon dioxide during a passive leg raising test, inferior vena cava distensibility were not associated with fluid appropriateness in our cohorts. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 17
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- PLoS ONE
- Publication Type :
- Academic Journal
- Accession number :
- 163793184
- Full Text :
- https://doi.org/10.1371/journal.pone.0285935